Results 11 to 20 of about 1,075,245 (301)

Short-term results of the management of severe bone defects in primary TKA with cement and K-wires [PDF]

open access: yesActa Orthopaedica et Traumatologica Turcica, 2017
Objective: The aim of this study was to evaluate the results of cement and kirschner wire augmentation in the management of bone defects in primary TKA.
Muhammet Sadik Bilgen   +2 more
doaj   +3 more sources

Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection [PDF]

open access: yesNanoscale Research Letters, 2011
Abstract Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems.
Gulati, K., Aw, M., Losic, D.
openaire   +7 more sources

Evaluation of reversal osteofixation using K-wires in digital replantation [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2014
Introduction. Modified, reversal technique of fixation in digital replantation using K-wires was analyzed. The results obtained from the standard technique and reversal technique of fixation using K-wires were compared. Objective. The aim was to
Vučetić Čedomir   +7 more
doaj   +2 more sources

Biodegradable nanocomposite coatings accelerate bone healing: In vivo evaluation

open access: yesDental Research Journal, 2015
Background: The aim of this study was to evaluate the interaction of bioactive and biodegradable poly (lactide-co-glycolide)/bioactive glass/hydroxyapatite (PBGHA) and poly (lactide-co-glycolide)/bioactive glass (PBG) nanocomposite coatings with bone ...
Mehdi Mehdikhani-Nahrkhalaji   +8 more
doaj   +2 more sources

An effective aesthetic toe-shortening procedure [PDF]

open access: yesArchives of Aesthetic Plastic Surgery, 2023
Background Many people with a longer second toe or lesser toes experience symptoms such as corns, hammertoe, and numerous others, especially when wearing open-toe shoes.
Bok Ki Jung   +3 more
doaj   +1 more source

Thin bonding wires temperature measurement using optical fiber sensors [PDF]

open access: yes, 2011
In this work we demonstrate the use of optical fiber sensors to measure temperature in thin metallic bonding wires. Temperature was measured in copper wires with diameter of 0.10, 0.28, 0.60 and 0.70 mm and for different values of the driven electrical ...
P. Antunes   +14 more
core   +1 more source

An investigation into the aerodynamic characteristics of catenary contact wires in a cross-wind [PDF]

open access: yes, 2001
An experimental analysis of the aerodynamic characteristics of catenary contact wires is presented. The aerodynamic data obtained were used to calculate the Glauert-Den Harthog criterion for one-dimensional galloping.
Scanlon, T.J., Stickland, M.T.
core   +3 more sources

Novel mesh suture may resist bone cutting seen with wire-based sternal closuresCentral MessagePerspective

open access: yesJTCVS Techniques, 2023
Objective: Sternal dehiscence is frequently associated with wire-based closures cutting through fragile bone, allowing sternal motion, separation, and infection. We investigated whether bone cutting could be limited by using a newly available mesh suture
Sandeep N. Bharadwaj, MD   +3 more
doaj   +1 more source

Hollow Notched K‐Wires for Bone Drilling With Through‐Tool Cooling [PDF]

open access: yes, 2019
Kirschner wire (K‐wire) is a common tool in clinical orthopedic surgery for bone fracture fixation. A significant amount of heat is generated in bone drilling using K‐wires, causing bone thermal necrosis and osteonecrosis.
Lei Chen   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy