Results 71 to 80 of about 1,907,351 (208)
This study investigated the role of two technical features of borehole heat exchangers (BHEs) in causing impacts on groundwater quality: the use of propylene glycol (PG) and other additives in heat-carrier fluids and the BHE grouting. The PG is the most diffused antifreeze compound used in heat-carrier fluids circulating into the ground loops ...
Arianna Bucci +6 more
openaire +2 more sources
Abstract Groundwater contamination has become an increasingly critical environmental concern worldwide. In situ chemical oxidation (ISCO) is considered a promising technology for groundwater remediation, but its performance in heterogeneous aquifers is often constrained by mass‐transfer limitations in low‐permeability zones, leading to suboptimal ...
Liu Yang +5 more
wiley +1 more source
Oil Circulation Effects on Evaporation Heat Transfer in Brazed Plate Heat Exchanger using R134A [PDF]
Experimental study was performed for oil circulation effects on evaporation heat transfer in the brazed type plate heat exchangers using R134A. In this study, distribution device was installed to ensure uniform flow distribution in the refrigerant flow ...
Chang, Youngsoo +2 more
core
Data for "Numerical simulation of a Deep Borehole Heat Exchanger in the Krafla geothermal system"
Data related to the paper: "Numerical simulation of a Deep Borehole Heat Exchanger in the Krafla geothermal ...
Patrick Verdin (2593777) +1 more
core +2 more sources
A semi-analytical temperature solution for multi-segment deep coaxial borehole heat exchangers
A semi-analytical and a finite-difference scheme are presented for the simulation of temperature and the heat transfer in a multi-segment coaxial borehole heat exchanger.
Magnus Wangen
doaj +1 more source
Ground source heat pump (GSHP) systems for heating and cooling represent an efficient alternative to conventional air source heat pump systems, always provided that they present an efficient design and operation.
Corberán, José M. +13 more
core +1 more source
Thermal Response Testing of a Multiple Borehole Ground Heat Exchanger
This paper presents the methodology, results and a discussion of thermal response tests (TRTs)performed on a multiple borehole ground heat exchanger. The ground heat exchanger consisted of nine80-m deep boreholes. TRTs with durations between 48 and 260 h
Javed, Saqib,, Fahlén, Per,
core +2 more sources
The thermal performance of foundation piles used as heat exchangers in ground energy systems
Pile heat exchangers are expected to make a significant contribution to meeting UK and EU renewable energy and carbon dioxide reduction targets. However, design for the thermal capacity of pile heat exchangers has to date been largely based on methods ...
Loveridge, F., Loveridge, Fleur
core +1 more source
R32 Partial Condensation Inside A Brazed Plate Heat Exchanger [PDF]
It is well known that when a superheated gas reaches a cold surface, the condensation starts immediately only if the wall temperature is lower than the dew temperature of the refrigerant; in this case, the heat transfer phenomenon can be also affected by
Mancin, Simone +2 more
core +1 more source
This paper describes the characteristics of a thermal response test and presents the results of the test conducted on a borehole at the freezing shaft in Poland.
Tomasz Sliwa +4 more
doaj +1 more source