Results 1 to 10 of about 1,960,167 (259)
Some of the next articles are maybe not open access.
Journal of Fluids and Structures, 2021
Central-slotted box girders are widely employed in long-span bridges owing to their advantageous flutter stability. However, the existence of a central slot can degrade their performance under vortex-induced vibrations (VIVs).
Sheng-Yuan Liu +4 more
semanticscholar +1 more source
Central-slotted box girders are widely employed in long-span bridges owing to their advantageous flutter stability. However, the existence of a central slot can degrade their performance under vortex-induced vibrations (VIVs).
Sheng-Yuan Liu +4 more
semanticscholar +1 more source
Experimental investigation of focused wave action on coastal bridges with box girder
, 2021The waves generated by hurricanes, together with storm surges, have led to severe damage and even failures in many coastal bridges in the Gulf of Mexico.
Qing-He Fang +4 more
semanticscholar +1 more source
Structure and Infrastructure Engineering, 2022
Extreme vertical impact loading from dropped heavy cargo or falling rocks threatens the safety of bridge structures. The impact behavior and post-impact performance of a multi-piece prestressed concrete (PC) box girder bridge were investigated through ...
Jing-Feng Zhang +6 more
semanticscholar +1 more source
Extreme vertical impact loading from dropped heavy cargo or falling rocks threatens the safety of bridge structures. The impact behavior and post-impact performance of a multi-piece prestressed concrete (PC) box girder bridge were investigated through ...
Jing-Feng Zhang +6 more
semanticscholar +1 more source
Journal of Fluids and Structures, 2021
To investigate the characteristics of vortex-induced vibration (VIV) of the twin-box girder, we carried out the VIV wind tunnel tests. The VIV of the twin-box girder occurs in the range of 4.680 ≤ U r ≤ 6.113, with the maximum dimensionless VIV ...
Buchen Wu, Shujin Laima
semanticscholar +1 more source
To investigate the characteristics of vortex-induced vibration (VIV) of the twin-box girder, we carried out the VIV wind tunnel tests. The VIV of the twin-box girder occurs in the range of 4.680 ≤ U r ≤ 6.113, with the maximum dimensionless VIV ...
Buchen Wu, Shujin Laima
semanticscholar +1 more source
Long-term temperature field of steel-box girder of a long-span bridge: Measurement and simulation
, 2021The temperature field of a long-span bridge is variant with an underlying statistical property due to the periodically time-varying solar radiation and the unceasing structural heat exchange with surrounding environment.
T. Tao +5 more
semanticscholar +1 more source
International Journal of Mechanical Sciences, 1975
Abstract The influence of rigidity and spacing of diaphragms on the deformation of a thin-walled one- to four-cell beam cross-section symmetrical about two axes was studied. The end cross-section of a simply supported beam subjected to antisymmetric loads applied mid-span of the beam keeps its shape and allows warping of the cross-section.
Djubek, J., Balaz, I.
openaire +2 more sources
Abstract The influence of rigidity and spacing of diaphragms on the deformation of a thin-walled one- to four-cell beam cross-section symmetrical about two axes was studied. The end cross-section of a simply supported beam subjected to antisymmetric loads applied mid-span of the beam keeps its shape and allows warping of the cross-section.
Djubek, J., Balaz, I.
openaire +2 more sources
, 2021
This paper will present a comparative study of tsunami-induced forces on box girder and T-girder bridges, which will be based on component level analysis.
Zhi-Ying Yang +4 more
semanticscholar +1 more source
This paper will present a comparative study of tsunami-induced forces on box girder and T-girder bridges, which will be based on component level analysis.
Zhi-Ying Yang +4 more
semanticscholar +1 more source
Engineering structures, 2021
This research proposes an innovative steel–concrete joint, which utilizes front and rear bearing plates and concrete filled steel cells, for long-span railway hybrid box girder cable-stayed bridges.
Ya-Dong Yao +4 more
semanticscholar +1 more source
This research proposes an innovative steel–concrete joint, which utilizes front and rear bearing plates and concrete filled steel cells, for long-span railway hybrid box girder cable-stayed bridges.
Ya-Dong Yao +4 more
semanticscholar +1 more source
Journal of Zhejiang University: Science A, 2022
Spatial and temporal temperature variations are critical for concrete box girders, and non-uniform temperature distributions induced by solar radiation depend on the structural shapes and shadows cast on them.
Tao Shi +3 more
semanticscholar +1 more source
Spatial and temporal temperature variations are critical for concrete box girders, and non-uniform temperature distributions induced by solar radiation depend on the structural shapes and shadows cast on them.
Tao Shi +3 more
semanticscholar +1 more source
Analysis of Box Girders with Diaphragms
Journal of the Structural Division, 1968Analyses based on thin-walled beam theory are presented for multicell box girders of deformable cross section. The influence of flexible interior diaphragms on stresses arising from deformation of the cross section is investigated for torsional loadings and box-cell properties appropriate for steel and reinforced concrete highway bridges.
Sana R. Abdel-Samad +2 more
openaire +1 more source