Results 151 to 160 of about 913,912 (191)
Some of the next articles are maybe not open access.
Capacity management in the short break market
International Journal of Contemporary Hospitality Management, 1997Considerable literature exists on the nature of yield management (YM) and capacity strategies. One strategy for maximizing revenue yield, rooms or supplementary spend is the provision of short breaks. Short breaks in the UK are widely recognized as a growth market.
openaire +2 more sources
DNA strand breaking capacity of acrylamide and glycidamide in mammalian cells
Mutation Research/Genetic Toxicology and Environmental Mutagenesis, 2005We compared the DNA damaging potency of acrylamide (AA) and its metabolite glycidamide (GA) in the comet assay in cell systems differing with respect to species origin and cytochrome P450-depended monooxygenase (CYP2E1) expression (V79, Caco-2, primary rat hepatocytes).
Nicole, Puppel +3 more
openaire +2 more sources
Optimal capacity of graded-response perceptrons: a replica-symmetry-breaking solution
Journal of Physics A: Mathematical and General, 1996Summary: Optimal capacities of perceptrons with graded input-output relations are studied within the first-step replica-symmetry-breaking Gardner approach [\textit{E. Gardner}, ibid. 21, 257 \textit{ff} (1988); Europhys. Lett. 4, 481 \textit{ff} (1988)]. Input-data errors and a limited output precision are allowed.
Bollé, D., Erichsen, R. jun.
openaire +1 more source
New interruption method for low-voltage, small-capacity, air-break contactors
Conference Record of the IEEE Industry Applications Society Annual Meeting, 1991An interruption method for low-voltage, small-capacity, air-break contactors is developed. The features of the construction of this method are that a slit is formed in the stationary conductor with a contact, and an arc runner is located on the slit. The operation, construction, experimental conditions and results, and applications of the method are ...
T. Mori, K. Koyama, H. Okado, S. Masuda
openaire +1 more source
Bridging Gaps, Breaking Barriers, and Building Capacities in Online Marketplaces
2022As the Fourth Industrial Revolution transforms the conduct of work and enterprises, inequalities and the digital-spatial divide become front and center of conversations that aim to promote online marketplaces and maximize their benefits. This paper takes stock of the development in human capital, labor market, and e-commerce, identifies state-led ...
Bayudan-Dacuycuy, Connie +1 more
openaire +2 more sources
Breaking barriers to agroforestry: FAO’s global capacity needs assessment
Tropical Forest IssuesThe FAO's Global Agroforestry Capacity Needs Assessment (CNA) revealed persistent challenges which are hindering widespread adoption of agroforestry despite its recognised benefits. Three primary action areas were identified: transforming agroforestry into an economically viable production system; strengthening enabling environments through ...
Elaine Springgay, Priya Pajel
openaire +1 more source
Time/current characteristics and breaking capacity of experimental vacuum fuses
IEEE Transactions on Electrical Insulation, 1993Conventional HV fuses, which are filled with quartz sand, have an excellent current-limiting capability, but they have a zone of uncertain operation in the low overcurrent range. To overcome this disadvantage, substituting of the quartz sand by a vacuum was considered.
D. Brechtken, D. Konig
openaire +1 more source
Breaking the Highway Capacity Barrier: Adaptive Cruise Control-Based Concept
Transportation Research Record: Journal of the Transportation Research Board, 1999A single-lane advanced vehicle-highway concept that can increase driving comfort and highway capacity is proposed. The concept can be implemented in the near future as it uses the adaptive cruise control (ACC) technology on vehicles and the intelligent ramp metering technologies on the roadway.
Datta N. Godbole +3 more
openaire +1 more source
Test Circuit for Evaluation of Breaking Capacity of Motor Starters
IEEE Transactions on Industry and General Applications, 1967Series RL circuits having a power factor between 40 and 50 percent with a resistor shunting the inductor and drawing one percent of the power are presently used for evaluating breaking capacity of motor starters. Transient recovery voltages of these circuits show anomalies which indicate that test circuits in different laboratories may have widely ...
Charles K. Eckels, Lynn H. Matthias
openaire +1 more source
Estimating arc temperature in a model high breaking capacity fuse
Australian Journal of Electrical and Electronics Engineering, 2004We present estimates of the temperature at different times during the arcing period of an experimental model of a sand-filled, high-voltage, high breaking capacity fuse. The model fuse does not interrupt current automatically but the technique described here could well be used in actual current-limiting high-voltage fuses to measure the time-resolved ...
Muhammad A. Saqib +3 more
openaire +1 more source