Results 171 to 180 of about 970,917 (377)

Biological and Mechanical Limitations for Chronic Fast‐Scan Cyclic Voltammetry Sensor Design

open access: yesAdvanced Materials Technologies, EarlyView.
Real‐time detection of neurochemicals has demonstrated value in the field of neuroscience. However, current methods have limitations for use in the chronic setting, which is often the ideal environment for research. This article discusses these limitations, as well as technologies that have been developed to overcome them, and provides recommendations ...
Mason L. Perillo   +6 more
wiley   +1 more source

High Fidelity Waveguides Through Vitreous Media Recomposition for Next Generation Photonic Devices

open access: yesAdvanced Optical Materials, EarlyView.
A newly designed aluminosilicate glass enables the fabrication of femtosecond laser‐written optical waveguides with ultra‐low propagation losses of −0.020 dB cm−1 at 1310 nm and −0.037 dB cm−1 at 1550 nm. Raman, Brillouin, and electron microscopy analyses reveal the mechanisms behind refractive index modifications, highlighting the role of glass ...
T Toney Fernandez   +9 more
wiley   +1 more source

The Impact of Donor‐Orientation on the Emission Properties of Chlorinated Trityl Radicals

open access: yesAdvanced Optical Materials, EarlyView.
Chlorinated trityl radicals with electron‐donating groups enable efficient red emission for optoelectronics. Donor orientation and steric constraints regulate vibronic coupling, influencing luminescence. A novel trityl derivative with restricted donor alignment minimizes non‐radiative decay, enhancing quantum yield.
Mona E. Arnold   +9 more
wiley   +1 more source

Coupled Optical Response of Armchair Graphene Nanoribbons and Single Wall Carbon Nanotube Hybrid Structures

open access: yesAdvanced Optical Materials, EarlyView.
A strong interaction between the five‐armchair graphene nanoribbons (GNRs) and the encapsulating single‐walled carbon nanotubes is identified. A reduction of the bandgap of the hybrid structure as well as additional proof for the single H‐terminations of the GNRs are confirmed through a combination of optical absorbance spectroscopy and density ...
Dido Denier van der Gon   +8 more
wiley   +1 more source

Operation and testing of Mark 10 Mod 3 underwater breathing apparatus [PDF]

open access: yes
Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing ...
Milwee, W. I., Jr.
core   +1 more source

Home - About - Disclaimer - Privacy