Results 11 to 20 of about 12,311 (186)

Fracture of the Femoral Broach Locking Mechanism and Surgical Technique to Retrieve the Broach [PDF]

open access: yesArthroplasty Today
The current case series reports on 4 cases of intraoperative fracture of the femoral broach locking mechanism during total hip arthroplasty and subsequent entrapment of the broach.
Peter P Hsiue   +2 more
exaly   +5 more sources

Simulation and research of cylindrical broach structures stress-strain state in solidworks system [PDF]

open access: yesMATEC Web of Conferences, 2019
The authors considered a methodology for the automated design of cylindrical broach structures consisting of the following stages: forming a 3D-parametric geometrical broach image, assessing a broach structure stress-strain state during operation.
Lukina Svetlana   +2 more
doaj   +2 more sources

Novel Strategy for Incarcerated Broken Broach Retrieval in Total Hip Arthroplasty [PDF]

open access: yesJournal of Orthopaedic Case Reports
Introduction: The goal of femoral component positioning in cementless total hip arthroplasty (THA) is accurate restoration of joint biomechanics and a press fit between the implant and the endosteal surface of the proximal femur.
Sanjay Agarwala   +2 more
doaj   +2 more sources

CONSTRUCTION AND TECHNOLOGICAL ANALYSIS OF THE BROACH BLADE SHAPE USING THE FINITE ELEMENT METHOD [PDF]

open access: yesApplied Computer Science, 2017
The paper presents results of numerical FEM analyses of the process of broaching the groove using the Explicit module of the ABAQUS program. The impact of the blade geometry was presented and of the selected technological parameters of processing when ...
Stanisław BŁAWUCKI, Kazimierz ZALESKI
doaj   +3 more sources

STRENGTH ANALYSIS METHODS OF CIRCULAR PULL BROACH COGS [PDF]

open access: yesFiabilitate şi Durabilitate, 2010
A very big importance in a pull broach designing is represented by its mechanic computation, which trots out the pull broach resistance on various blank tooling, pull broach productivity and also the loadings which is subdued to and the stresses that ...
Cosmin MIRIŢOIU
doaj   +1 more source

Influence of femoral broach shape on stem alignment using anterior approach for total hip arthroplasty: A radiologic comparative study of 3 different stems. [PDF]

open access: yesPLoS ONE, 2018
BACKGROUND:Malalignment of the femoral stem in total hip arthroplasty (THA) can detrimentally affect outcome. Poor preparation of the femur intraoperatively is an important cause of stem malalignment.
Cécile Batailler   +3 more
doaj   +3 more sources

A Unique Complication of Femoral Broach Fracture and Incarceration During Total Hip Arthroplasty

open access: yesArthroplasty Today, 2021
In recent years, total hip arthroplasty via the direct anterior approach has been gaining popularity. It offers potential early advantages for less pain and quicker return of hip function; however, compared to other surgical approaches, it is associated ...
Andrzej Brzezinski, Michael Simon
exaly   +3 more sources

Optimal Bone Preparation for Triple-Tapered Stems: Does the Sagittal Taper Affect Optimal Femoral Sizing? [PDF]

open access: yesArthroplasty Today
Background: Conventional single-tapered, total hip arthroplasty stems achieve fixation namely through coronal, metaphyseal fit. Triple taper stems have a sagittal taper to optimize fixation in the antero-posterior (AP) plane as well; however, limited ...
Jeff Shi, MD   +5 more
doaj   +2 more sources

Quasi-static mechanical evaluation of canine cementless total hip replacement broaches: effect of tooth design on broach and stem insertion [PDF]

open access: yesBMC Veterinary Research
Background Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion.
Zachary T. Lawson   +5 more
doaj   +2 more sources

Short- and Mid-term Radiographic Outcomes of Ream-then-broaching Metaphyseal Cones During Revision Total Knee Arthroplasty [PDF]

open access: yesArthroplasty Today
Background: The purpose of this study is to assess the short- and mid-term radiographic outcomes of a ream-then-broach metaphyseal cone design for revision total knee arthroplasty (rTKA).
Aria Darbandi, MD   +8 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy