Results 31 to 40 of about 2,804 (163)

Microcontroller based bidirectional buck–boost converter for photo-voltaic power plant

open access: yesJournal of Electrical Systems and Information Technology, 2018
A common configuration for a stand-alone PV power system may consist of three converters: a buck converter for the PV panel to charge the battery, a boost converter for the battery to discharge to the load and one for the load voltage regulation.
Viswanatha V., Venkata Siva Reddy R.
doaj   +1 more source

Chaos in the buck converter

open access: yes, 2023
Esta tesis estudia el fenómeno del caos en las ecuaciones que modelan un convertidor buck con control PWM. Desde el punto de vista matemático, contribuye al estudio de los sistemas lineales a trozos tridimensionales, con émfasis en las perspectivas geométrica y de cálculo numérico.
openaire   +4 more sources

MPPT mechanism based on novel hybrid particle swarm optimization and salp swarm optimization algorithm for battery charging through simulink

open access: yesScientific Reports, 2022
In this paper, a battery charging model is developed for solar PV system applications. As a means of photovoltaic power controlling system, buck-boost converter with a Maximum Power Point Tracking (MPPT) mechanism is developed in this paper for maximum ...
Idriss Dagal, Burak Akın, Erdem Akboy
doaj   +1 more source

Bi-Stability Phenomenon in Constant On-Time Controlled Buck Converter With Small Output Capacitor ESR

open access: yesIEEE Access, 2018
This paper reports the finding of bi-stability phenomenon in a constant on-time (COT) controlled buck converter with a small output capacitor equivalent series resistance (ESR).
Xi Zhang   +4 more
doaj   +1 more source

Circuit Configurable Bidirectional DC-DC Converter for Retired Batteries

open access: yesIEEE Access, 2021
Due to the rapid development and widespread usage of Electric Vehicles (EVs), there will be more and more retired batteries in the future. These retired batteries can be used in energy storage systems to stabilize smart grid operation with high ...
Jenhao Teng   +3 more
doaj   +1 more source

DESIGN AND SIMULATION OF POWER FACTOR CORRECTION FOR AC/DC CONVERETER

open access: yesJournal of Engineering, 2008
One of the biggest problems in power quality aspects is the harmonic contents in the electrical system. Most of the current harmonics are due to the nonlinear operation of the power converters and arc furnaces .
Amina Mahmoud Shaker   +2 more
doaj   +1 more source

Two-Parameter Bifurcation Analysis of the Buck Converter [PDF]

open access: yesSIAM Journal on Applied Dynamical Systems, 2009
This paper is concerned with the analysis of two-parameter bifurcation phenomena in the buck power converter. It is shown that the complex dynamics of the converter can be unfolded by considering higher codimension bifurcation points in two-parameter space.
Alessandro Colombo   +3 more
openaire   +5 more sources

A Single-Phase Bidirectional AC/DC Converter for V2G Applications

open access: yesEnergies, 2017
This paper presents a single-phase bidirectional current-source AC/DC converter for vehicle to grid (V2G) applications. The presented converter consists of a line frequency commutated unfolding bridge and an interleaved buck-boost stage.
Tao Peng   +8 more
doaj   +1 more source

A modified two-stage isolated bidirectional buck-DAB converter with a full-load ZVS range

open access: yesFrontiers in Energy Research
A modified two-stage buck-DAB (MBDAB) converter is proposed to improve the performance of the traditional two-stage buck-DAB (TSBDAB) converter. In the MBDAB converter, the DAB can work with fixed voltage gain and voltage-matched condition under a wide ...
Jinliang Li   +5 more
doaj   +1 more source

A high efficiency non-inverting multi device buck-boost DC-DC converter with reduced ripple current and wide bandwidth for fuel cell low voltage applications [PDF]

open access: yesSerbian Journal of Electrical Engineering, 2018
The voltage produced by the fuel cell (FC) device is unregulated and varies from 0.4 V to 0.8 V on full load to no-load respectively. When these devices are used in low voltage applications and output voltage lies between higher and lower values of input
Venkatesh Naik M., Samuel Paulson
doaj   +1 more source

Home - About - Disclaimer - Privacy