Results 111 to 120 of about 7,161,196 (237)

Analysis of timber as sustainable material for construction [PDF]

open access: yes, 2014
Comunicació presentada a IN-TECH 2014 International Conference on Innovative Technologies (Leiria, Portugal 10-13, september 2014).Facing the climate change scenario, professionals and technicians of civil engineering and architecture are searching for ...
Braulio-Gonzalo, Marta   +2 more
core  

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

Accuracy and reproducibility of a single‐pose image‐to‐robot registration method for mobile C‐arm cone beam CT guided histotripsy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Histotripsy is a focal tumor therapy that utilizes focused ultrasound (US) to mechanically destroy tissue. To overcome visualization limitations of diagnostic US‐guidance, C‐arm cone beam CT (CBCT)‐guided histotripsy is being developed, for which a mobile C‐arm could increase accessibility. CBCT‐guided histotripsy uses a phantom with a
Grace M. Minesinger   +5 more
wiley   +1 more source

Comprehensive end‐to‐end dosimetry audit for stereotactic body radiotherapy in spine, lung, and soft tissue

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To create and conduct a comprehensive onsite end‐to‐end dosimetry audit to assess treatment accuracy of spine, lung, and soft tissue Stereotactic Body Radiotherapy (SBRT) across Australian and New Zealand (ANZ) radiotherapy centers. Methods The Australian Clinical Dosimetry Service (ACDS) anthropomorphic thorax phantom underwent a CT ...
Maddison Shaw   +8 more
wiley   +1 more source

CNS Mitochondria‐Derived Vesicle in Blood: Potential Biomarkers for Brain Mitochondria Dysfunction

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Mitochondrial dysfunction is a hallmark of neurodegenerative diseases like Alzheimer's (AD) and Parkinson's (PD). Our goal was to develop practical, noninvasive methods to assess mitochondrial status through the detection of mitochondria‐derived vesicles (MDVs).
Qi Liu   +12 more
wiley   +1 more source

Home - About - Disclaimer - Privacy