The Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study. [PDF]
Mizuno M +11 more
europepmc +1 more source
Selecting a Grounding Scheme for Screens of Power Cable Lines
openaire +1 more source
Recent Advances in Shade Selection in Dentistry.
Paharia R +4 more
europepmc +1 more source
Related searches:
Screening attenuation of differential cable-connector assemblies
Proceedings. 45th Annual IEEE Symposium on Foundations of Computer Science, 2005High speed data transmission is now required in many applications. One limiting factor on speed can be radiated emissions. This paper presents simulation and measurement results on electromagnetic leakage of various differential cable connector assemblies. Leakage modelling aspects are also considered. Differential and common mode interferences as well
A. Hekkala, T. Tarvainen
openaire +1 more source
Different Screen Arrangements of Distribution Insulated Cables
2018 AEIT International Annual Conference, 2018The distribution cables can be operated with their metallic screens in solid bonding (bonded and earthed at both ends) or in single-point bonding (bonded and earthed only at secondary station earthing grid). Each arrangement has pros and cons and the final choice depends upon the cable line length and the earth potential rise of the primary substation.
Benato, Roberto +5 more
openaire +1 more source
Broadband Frequency Domain Screening Measurements on RF-Cables
1988 18th European Microwave Conference, 1988The measurement of screening effectiveness on cable assemblies is very difficult to perform over broad frequency ranges (e.g. from several kHz to more than 3 GHz). A new type of test set-up has been developed and tested with a transmission type wire injection principle.
B. Eicher +3 more
openaire +1 more source
Screening of cables and connectors
Electronics & Communication Engineering Journal, 1994Cable and connector screening is given as transfer impedance, which relates a voltage seen inside the component to the current on its outside. One transient disturbance comes from switching on the local mains network, which results in large RF currents flowing in an instrument cable nowhere near the original source. The effect of this current on cables
openaire +1 more source
Prediction of leakage from single braid screened cables
IEE Proceedings A Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1986Theoretical predictions for the surface transfer impedances of braided coaxial cables are compared to measured values. A phenomenon is reported, whereby the measured cable leakage does not vary linearly with frequency. The predictions include manufacturing tolerances of the braid, this leads to the conclusion that at least a maximum leakage is ...
P.A. Cudd, F.A. Benson, J.E. Sitch
openaire +1 more source
Derating Factor for Cable Crossings With Consideration of Longitudinal Heat Flow in Cable Screen
IEEE Transactions on Power Delivery, 2004In this paper, an extension of the previously published method for the calculation of the derating factors for cables crossing external heat sources is proposed. The extension takes into account the longitudinal heat flow in cable metallic screen. The proposed algorithm is illustrated in a numerical example considering a practical situation of a high ...
G.J. Anders, E. Dorison
openaire +1 more source
A Screening Attenuation Evaluation Method for HEV Power Cable
SAE Technical Paper Series, 2008<div class="htmlview paragraph">This paper proposes a new screening attenuation evaluation method (PHSA) for hybrid power cables. Hybrid power cables connect battery, inverter and motor. As the noise and shield characteristics of these cables are different from general communication shield wires, new method for evaluating screening attenuation is
Liang Zhong +9 more
openaire +1 more source