Results 11 to 20 of about 6,965 (218)
Study on the Influence of Winding Height on the Short-Circuit Withstand Capability of 110 kV Transformers [PDF]
The short-circuit withstanding capability of a transformer is a critical indicator for evaluating its operational reliability. This study investigates the influence of the low-voltage winding height, a key structural parameter, on the electromagnetic ...
Yukun Ma +7 more
doaj +2 more sources
Currents in the overhead transmission line lighting wire in case of single-phase short circuit
The algorithms for currents induced in a grounded lightning wire (LW) with single-phase short circuit (SC) calculation are considered. It is shown that the method of short-circuit current and current in LW simultaneous determination gives more correct ...
Zimin Kirill +3 more
doaj +1 more source
When calculating short circuit currents in the traction network, it is necessary to take into account the input resistance of the traction substation, including the resistance of the transformers of the substation and the resistance of the power supply ...
E. P. Figurnov +2 more
doaj +1 more source
Rotor winding short circuit faults are common faults for variable-speed pumped-storage generator-motors (VSPSGM). At present, the exciting rotor fault protection of VSPSGM is simple and has low sensitivity. It can only act when the instantaneous value of
Jian Qiao +6 more
doaj +1 more source
. A method is proposed for calculating the initial value of the periodic term of the short- circuit strength of a dual-circuit overhead transmission line using multiphase replacement circuits. The method takes into account the electromagnetic connections
R. U. Galeeva +2 more
doaj +1 more source
Existing short-circuit calculation methods for distribution networks with renewable energy sources ignore the fluctuation of renewable sources and cannot reflect the impact of renewable sources and load changes on short-circuit current in real time at ...
Dan Liu +5 more
doaj +1 more source
Algorithm and Software for Operative Calculations of the Short Circuits Modes
Smart power grids provide efficient control of power flows or other grid variables, such as voltages or short circuit currents. Most essential the control has become, if the consumers are electrical systems of high power capacity.
Borisov Stanislav V. +2 more
doaj +1 more source
A Short-Circuit Calculation Method for DFIG-Based Wind Farms
Short-circuit calculations for wind farms are crucial for determining equipment ratings and providing basic information for protection coordination. In this paper, a practical calculation method of short-circuit currents (SCCs) is proposed for doubly fed
Mingyang Liu +5 more
doaj +1 more source
Fault currents of inverter‐interfaced distributed generators (IIDGs) depend on inverter controllers. Thus, IIDGs fault currents are different than those of synchronous‐based DGs, both from the magnitude and waveshape perspectives.
Talal Elemamali Sati, Maher A. Azzouz
doaj +1 more source
DC short-circuit faults are one of the challenges for modular multilevel converter (MMC) based DC grid. It is vital for proper design of protection system to estimate the fault currents and voltages.
Hui Cai +3 more
doaj +1 more source