Reliability of caloric testing
Irish Journal of Medical Science (1971 -), 2021To assess the long-term stability of caloric testing in patients.In this retrospective study, Cronbach's alpha was used to determine whether caloric testing results are stable over time (up to 7 years) in patients who have not undergone interventions.
Brian W. Blakley, Nasser Barakat
openaire +2 more sources
Acta Oto-Laryngologica, 1961
A simple device for fixing both head and body of the cat was designed so that the nystagmic reaction to caloric stimulation could be investigated. Nystagmographie tracings of both ordinary and derived nystagmus were obtained being relatively free of artifacts induced by movements.In order to produce a caloric reaction in the cat, it was necessary to ...
N G, HENRIKSSON +2 more
openaire +2 more sources
A simple device for fixing both head and body of the cat was designed so that the nystagmic reaction to caloric stimulation could be investigated. Nystagmographie tracings of both ordinary and derived nystagmus were obtained being relatively free of artifacts induced by movements.In order to produce a caloric reaction in the cat, it was necessary to ...
N G, HENRIKSSON +2 more
openaire +2 more sources
2016
The test of caloric thermal irrigations is one of the first tests for sensitivity of the peripheral vestibular systems dating to the late 1800s. This chapter reviews the various protocols that have been developed over the years using thermal irrigations to the external auditory canals.
N T, Shepard, G P, Jacobson
openaire +2 more sources
The test of caloric thermal irrigations is one of the first tests for sensitivity of the peripheral vestibular systems dating to the late 1800s. This chapter reviews the various protocols that have been developed over the years using thermal irrigations to the external auditory canals.
N T, Shepard, G P, Jacobson
openaire +2 more sources
Otolaryngology–Head and Neck Surgery, 1984
The caloric test is still the most useful vestibular test by far. Rotatory tests may allow more accurate control of the stimulus and the response parameters may vary less in normal individuals, but only the caloric test allows individual testing of each ear.
openaire +2 more sources
The caloric test is still the most useful vestibular test by far. Rotatory tests may allow more accurate control of the stimulus and the response parameters may vary less in normal individuals, but only the caloric test allows individual testing of each ear.
openaire +2 more sources
Archives of Otolaryngology - Head and Neck Surgery, 1957
There are many caloric tests; some are simple, some are complex. They vary in accuracy and in the amount of information obtainable. We are all familiar with most of these. There is no reason to discuss them at this time. The test described here is certainly not new (although I have not seen it in the literature) and is probably used by many of us.
openaire +2 more sources
There are many caloric tests; some are simple, some are complex. They vary in accuracy and in the amount of information obtainable. We are all familiar with most of these. There is no reason to discuss them at this time. The test described here is certainly not new (although I have not seen it in the literature) and is probably used by many of us.
openaire +2 more sources
Ear and Hearing, 1986
The standard ABB remains the most popular test of vestibular function. The use of air caloric irrigations or the closed loop water system seem to be scientifically sound alternatives to the use of open water irrigation. Although controversy still surrounds the use of monothermal warm calorics as a screening test, several studies have shown its ...
openaire +2 more sources
The standard ABB remains the most popular test of vestibular function. The use of air caloric irrigations or the closed loop water system seem to be scientifically sound alternatives to the use of open water irrigation. Although controversy still surrounds the use of monothermal warm calorics as a screening test, several studies have shown its ...
openaire +2 more sources
The caloric vestibular test in weightlessness
Archives of Oto-Rhino-Laryngology, 1987Although the theoretical background for the caloric vestibular test was assumed to be known, recent studies in weightlessness have thrown doubts on the original theory of its mechanism. It is most likely that several mechanisms are involved in the generation of caloric nystagmus in addition to the convection current theory. Experiments with the caloric
W J, Oosterveld, H A, de Jong
openaire +2 more sources
Evaluation of the monothermal caloric test
The Laryngoscope, 1989AbstractIn 1970, Torok reported that patients with labyrinthine disease showed vestibular recruitment and that patients with retrolabyrinthine disease showed vestibular decruitment on the monothermal caloric test. Other investigators have failed to confirm these findings; however, their studies did not precisely replicate Torok's test procedure ...
S A, Bhansali +3 more
openaire +2 more sources
Caloric Tests In Deaf Children
Archives of Otolaryngology - Head and Neck Surgery, 1965T THERE ARE only a few reports in the literature concerning the vestibular reactivity in children that suffer from severe sensorineural impairment of hearing. Shambaugh et al 13 collected, in 1930, information about 5,348 children from schools for the deaf in the US.
L E, SANDBERG, K, TERKILDSEN
openaire +2 more sources
A microbiological hazard in caloric testing
British Journal of Audiology, 1991The use of caloric testing is widespread in hospital audiology departments. This paper describes contamination of the caloric water tanks with the organism Acinetobacter anitratus and the changes in practice instituted to eliminate this risk to patients.
D M, Baguley, J, Whipp, M, Farrington
openaire +2 more sources