Results 221 to 230 of about 1,010,401 (270)
Some of the next articles are maybe not open access.
Cancellous bone as an antibiotic carrier
Acta Orthopaedica Scandinavica, 2000We compared the release characteristics of antibiotics from in vivo and in vitro processed morselized cancellous bone. The bone was impregnated with 7 antibiotics and compressed into a wire-mesh cylinder. In vitro, the bone was processed by daily transfer of the cylinder with its contents into test tubes with broth. The amount of antibiotic eluted from
E, Witsø +4 more
openaire +2 more sources
Thermal properties of cancellous bone
Journal of Biomedical Materials Research, 1975AbstractSpecimens of beef bone were analyzed for thermal conductivity and thermal capacity. The thermal conductivity was about 7 × 10−4 cal/cm/sec/°C, that is about the same as for other tissues. As regards thermal capacity, the determination of 0.73 cal/cm2/°C also was similar to that in other tissues Both thermal conductivity and capacity were ...
R, Clattenburg +3 more
openaire +2 more sources
Penetration of Acrylic Bone Cements into Cancellous Bone
Acta Orthopaedica Scandinavica, 1983The depth of penetration of five commercial acrylic bone cements into cancellous bone was measured in vitro. Under standard, idealized conditions, cement penetration was found to vary significantly with different cements. Penetration was critically influenced by the coarseness of the cancellous bone and increased directly with the effective volume of ...
P C, Noble, E, Swarts
openaire +2 more sources
MECHANICAL PROPERTIES OF GLENOID CANCELLOUS BONE
Journal of Biomechanics, 2008Loosening of the glenoid component in total shoulder arthroplasty is the main late complication of this procedure; it may be assumed that it is highly dependent on the quality of the glenoid cancellous bone. Very little is known about the mechanical properties of this cancellous bone.
Kalouche, Ibrahim +5 more
openaire +3 more sources
A Synthetic Bone Implant Macroscopically Identical to Cancellous Bone
Biomaterials, 1998Macroporous hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) are widely used as synthetic bone replacement materials due to their high biocompatibility and osteoconductive properties. The level of porosity, pore size distribution, pore morphology, and the degree of pore interconnectivity in such grafts significantly influences the extent of
B A O McCormack, A J Carr
exaly +3 more sources
Journal of Biomechanics, 1999
Cancellous bone is both a biological and a mechanical structure. The interaction between these two aspects of cancellous bone is sufficiently strong that understanding the mechanical properties of the tissue is not possible without consideration of the biology.
D.P. Fyhrie, J.H. Kimura
openaire +1 more source
Cancellous bone is both a biological and a mechanical structure. The interaction between these two aspects of cancellous bone is sufficiently strong that understanding the mechanical properties of the tissue is not possible without consideration of the biology.
D.P. Fyhrie, J.H. Kimura
openaire +1 more source
Production of Autologised Cancellous Bone with the Use of Homologous Cancellous Bone
1989The free transplantation of cancellous bone is often used for the stimulation of osteogenesis, for the replacement of traumatic or pathologic bone defects and for the curing of nonunions. The effectiveness of transplantation depends not only upon the blood supply of the recipient bed but also upon the quantity and activity of cancellous bone.
A. Sárváry, G. Berentey
openaire +1 more source
Journal of Computer Assisted Tomography, 1991
Quantitative computed tomography is extensively used to assess bone density; its potential to quantify bone structure, however, remains to be explored. In this work we present the modifications of the run-length method necessary to enable an analysis of the trabecular bone structure at the distal radius and the distal tibia.
Eric P. Durand, Peter Rïegsegger
openaire +1 more source
Quantitative computed tomography is extensively used to assess bone density; its potential to quantify bone structure, however, remains to be explored. In this work we present the modifications of the run-length method necessary to enable an analysis of the trabecular bone structure at the distal radius and the distal tibia.
Eric P. Durand, Peter Rïegsegger
openaire +1 more source
The mechanical behaviour of cancellous bone
Journal of Biomechanics, 1985Cancellous bone has a cellular structure: it is made up of a connected network of rods and plates. Because of this, its mechanical behaviour is similar to that of other cellular materials such as polymeric foams. A recent study on the mechanisms of deformation in such materials has led to an understanding of how their mechanical properties depend on ...
openaire +2 more sources
Scattering of SH waves in compact bone and cancellous bone
Biomedical Signal Processing and Control, 2020Abstract The effectiveness of electrical stimulation and Pulsed Electro Magnetic Field (PEMF) stimulation for enhancement of bone healing and osteoporosis detection has been reported by many researchers. In this paper, the scattering of SH waves by the cavity is studied analytically by using the complex variable function method.
Meng Xiang, Hui Qi, Zhiwei Qu, Jing Guo
openaire +2 more sources

