Results 41 to 50 of about 151,073 (306)
Cell therapies typically rely on cold‐chain logistics and cryopreservation, limiting access and compromising cell quality. Here, a dual‐chamber device separates an oxygen‐supplying chamber from a hyaluronic acid cargo chamber, sustaining oxygen delivery for over 70 h and enabling ambient‐temperature shipment.
Daniel A. Domingo‐Lopez +9 more
wiley +1 more source
Inflow cannula design for biventricular assist devices [PDF]
Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required.
Gregory, Shaun David
core
The anatomical interaction between mechanical circulatory or respiratory support and the patient is achieved by specially designed tubes called cannulae.
Gregory, Shaun D. +11 more
core +1 more source
Extracorporeal Membrane Oxygenation Cannula Malposition
Malposition of the extracorporeal membrane oxygenation (ECMO) cannulas is not frequently reported in central cannulation technique: we aimed to present an ECMO cannula malposition in follow-up in a neonate case.
Osman Nuri Tuncer +3 more
core +1 more source
Design optimization of bidirectional arterial perfusion cannula.
Determine if shortening the covered section of a self-expanding bidirectional arterial cannula, can enhance retrograde flow and thus reduce the risk of lower limb ischemia.
Abdel-Sayed, P. +5 more
core +1 more source
A porous parylene‐coated electrode loaded with dexamethasone was developed to reduce inflammation after cochlear implantation. In guinea pigs, the device provided sustained drug release, maintained biocompatibility, improved auditory brainstem response thresholds, and reduced inflammatory cell infiltration and TNF‐α expression.
Chi‐Chieh Chang +11 more
wiley +1 more source
Effective utilisation of rapid infusion catheters in perioperative care: a narrative review
Summary: The Rapid Infusion Catheter (RIC) has transformed intravenous (i.v.) access, allowing for rapid fluid delivery peripherally. It may negate the need for a central vein sheath to be placed.
Adam Scorer +4 more
doaj +1 more source
A microfluidic method is presented which enables parallelized fabrication of rod‐shaped microgels, based on step‐emulsification (SE) droplet generation and subsequent droplet distribution and confinement, combined in a single device. Microgel rods are fabricated in parallel at different flow rates based on two light‐mediated crosslinking chemistries ...
Matthias Mork +5 more
wiley +1 more source
UCST‐Responsive PMEGA: From Solution Behavior to Functional Hydrogel Surfaces
PMEGA is used as a versatile water‐based UCST‐responsive platform for engineering microstructured hydrogel coatings via a thiol–ene CLAG approach. From PMEGAs of well‐defined UCST properties, the UV‐based CLAG method provides precise control over film thickness, ranging from nanometers to micrometers, and enables high‐resolution patterning.
Thi Phuong Thu Nguyen +4 more
wiley +1 more source
Arthroscopic Remplissage With Knotless All-Suture Anchors and Concomitant Bankart Repair: Technical Considerations. [PDF]
Abstract Anterior shoulder instability is common in active patients. Traumatic dislocations may produce Bankart and Hill‐Sachs lesions that increase recurrence risk. In high‐demand individuals, isolated Bankart repair may be insufficient for off‐track or near‐track Hill‐Sachs lesions.
Nocek M +6 more
europepmc +2 more sources