Background Self-lock compression anti-rotation blade (SCAB) is a novel internal fixation implant for femoral neck fractures (FNF). We conducted this finite element analysis study to evaluate the biomechanical performances of SCAB combined with a ...
Bo-Xuan Huang +3 more
doaj +1 more source
An approximate model for cancellous bone screw fixation [PDF]
This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2013 Taylor & Francis.This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved ...
A. Day +31 more
core +1 more source
Background Currently, cannulated pedicle screws have been widely used in minimal invasive or navigation techniques. However, the stress distribution and the strength of different core diameters of cannulated screw are not clear.
Chia-Ming Chang +2 more
doaj +1 more source
Biomechanical Evaluation of the Fixation Methods for Transcondylar Fracture of the Humerus:ONI Plate Versus Conventional Plates and Screws [PDF]
We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and ...
Hashizume, Hiroyuki +6 more
core +1 more source
Background and purpose: Minimally invasive spine surgery has continuously evolved for specific surgical procedures and patient populations to lower morbidity and the risk of postoperative bacterial infection.
Magnus A Hvistendahl +5 more
doaj +1 more source
Stereotactic guidance for navigated percutaneous sacroiliac joint fusion. [PDF]
Arthrodesis of the sacroiliac joint (SIJ) for surgical treatment of SIJ dysfunction has regained interest among spine specialists. Current techniques described in the literature most often utilize intraoperative fluoroscopy to aid in implant placement ...
Kim, Kee D +4 more
core +1 more source
Outcomes of total hip arthroplasty, as a salvage procedure, following failed internal fixation of intracapsular fractures of the femoral neck: a systematic review and meta-analysis. [PDF]
AIMS: The optimal management of intracapsular fractures of the femoral neck in independently mobile patients remains open to debate. Successful fixation obviates the limitations of arthroplasty for this group of patients.
Archibeck MJ +21 more
core +2 more sources
Use of Cannulated Screws for Primary Latarjet Procedures
Background: Rapid consolidation of the bone block is paramount for the success of the Latarjet procedure. Noncannulated screws have shown satisfactory long-term bone block fusion, while cannulated screws are challenged with inferior mechanical properties and fusion rates.
Rattier, Simon +5 more
openaire +2 more sources
Warwick hip trauma study : a randomised clinical trial comparing interventions to improve outcomes in internally fixed intracapsular fractures of the proximal femur : protocol for The WHiT Study [PDF]
Background Controversy exists regarding the optimal treatment for patients with displaced intracapsular fractures of the proximal femur. The recognised treatment alternatives are arthroplasty and internal fixation.
Achten, Juul +3 more
core +5 more sources
Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report
We present a case of arthroscopic fixation for bony Bankart lesion using a double-threaded cannulated screw. A 39-year-old man sustained a left shoulder injury from a motorcycle accident.
Takeshi Kokubu +3 more
doaj +1 more source