Results 111 to 120 of about 45,603 (231)

Complications and associated risk factors at screw removal in slipped capital femoral epiphysis treated by cannulated stainless steel screws

open access: yesJournal of Children's Orthopaedics, 2012
Purpose The aim of our study is to report our complication rate and analyze the associated risk factors when removing cannulated stainless steel screws for SCFE fixation.
Juan Pretell-Mazzini   +6 more
doaj   +1 more source

A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study

open access: yes, 2019
Fractures of the femoral neck are injuries commonly sustained by elderly patients due to osteoporosis and unsteadiness of gait. Cannulated screws are widely used for internal fixation as a treatment for femoral neck fractures as it has the advantage of ...
Ho, Phoebe Zi Qing
core  

Holding Power of Orthopaedic Screws in Bovine Femoral Heads

open access: yes, 1993
SummaryFemoral capital physeal fractures have been successfully repaired using 7.0 mm cannulated screws. The holding power of 7.0 mm cannulated screws was compared to the holding power of 5.5 mm cortical screws and 6.5 mm cancellous screws using paired ...
D. G. Wilson, M. J. Ulm
core   +1 more source

Error replication as an instructional strategy in simulation‐based procedural learning

open access: yesMedical Education, EarlyView.
Abstract Background Errors are an inevitable part of clinical learning, yet procedural training commonly emphasises error avoidance. This study examined the effect of deliberate replication of predefined procedural errors (Error Replication; ER), compared with error avoidance training (EAT), on post‐test performance, retention and transfer in surgical ...
Jacob Faurholdt   +3 more
wiley   +1 more source

Biomechanical comparisons of F.E.R.I. techniques with different type of intramedullary screws fixation for Jones fractures

open access: yesFrontiers in Bioengineering and Biotechnology
Introduction: Jones fractures frequently fail to unite, and adequate fixation stability is crucial. This study aimed to elucidate the biomechanical stability of various intramedullary screw fixation constructs.Methods: Jones fracture model over the ...
Kuo-Chih Su   +6 more
doaj   +1 more source

Cannulated screws

open access: yes, 2021
Sean Carter   +2 more
openaire   +1 more source

A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture : a finite element study

open access: yes, 2013
Femoral neck fractures are a common form of injury amongst the elderly and cannulated screws are the preferred choice for fixation. Previous studies have researched the performance of various screw design and configurations based on pull-out strength as ...
Du, Zhenglin.
core  

Treatment Trade‐Offs and Choices for Femoral Fractures: A Systematic Review and Meta‐Analysis

open access: yesOrthopaedic Surgery, Volume 17, Issue 5, Page 1298-1313, May 2025.
This review examines the trade‐offs between surgical intervention and traction therapy for adult and elderly patients with femoral fractures and surgical contraindications, particularly in resource‐limited settings. While intramedullary nailing may offer better clinical outcomes, traction therapy is often preferred due to limited surgical resources ...
Jiarui Li   +11 more
wiley   +1 more source

Closed reduction and percutaneous fixation of sacroiliac luxations in cats using 2.4 mm cannulated screws – a cadaveric study

open access: yes, 2012
SummaryObjectives: To describe fluoroscopically assisted percutaneous placement of 2.4 mm cannulated screws for fixation of artificially induced sacroiliac luxations in cats, and to evaluate the success of this technique in restoration of normal pelvic ...
J. Bokemeyer   +5 more
core   +1 more source

Clinical Outcomes of an Improved Arthroscopic Suture‐Bridge Technique Assisted by a “5 O'clock” Portal for Acute Bony Bankart Lesions

open access: yesOrthopaedic Surgery, EarlyView.
This modified arthroscopic suture‐bridge technique, utilizing a unique “5 o'clock” portal, achieves reliable perpendicular fixation for bony Bankart lesions, reducing mean glenoid bone loss from 18.2% to 2.5% (p < 0.001) with a 97.2% healing rate and 80% return‐to‐sport rate. ABSTRACT Purpose Bony Bankart lesion is a primary cause of traumatic shoulder
Fan Jiang   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy