Results 141 to 150 of about 245,619 (256)
Transcranial photobiomodulation with near‐infrared laser induces analgesia in rats
Abstract figure legend Transcranial photobiomodulation (tPBM) with a 1064 nm laser alleviated pain. Local field potential (LFP) intensity markedly increased following formalin injection, indicating nociceptive activation. However, after tPBM, this formalin‐induced LFP hyperactivation was diminished. Meanwhile, tPBM preserved brain connectivity that was
Zhen Wang +3 more
wiley +1 more source
A new concept for implant fixation: bone-to-bone biologic fixation [PDF]
Many attempts have been made to reduce complications of bone implant, such as pedicle screw loosening. To address this problem, the authors suggest a new concept of bone-to-bone biologic fixation using recombinant human bone morphogenetic protein-2 ...
D-Y Kim, J-R Kim, KY Jang, K-B Lee
doaj
Background Pedicle screws can be augmented with polymethylmethacrylate (PMMA) cement through cannulated and fenestrated pedicle screws to improve screw anchorage. To overcome the drawbacks of PMMA, a modified augmentation technique applying a self-curing
Werner Schmoelz +4 more
doaj +1 more source
Surgical treatment of upper, middle and lower cervical injuries and non-unions by anterior procedures [PDF]
The goals of any treatment of cervical spine injuries are: return to maximum functional ability, minimum of residual pain, decrease of any neurological deficit, minimum of residual deformity and prevention of further disability.
Aebi, Max
core
Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire
Purpose: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae.
Chih-Wei Chang +5 more
doaj +1 more source
Quantification of bone strength by intraoperative torque measurement: a technical note [PDF]
Introduction: Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis'
Haenni, Markus +4 more
core
Background The selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation.
Mehmet Maden +5 more
doaj +1 more source
Fixation principles in metaphyseal bone—a patent based review [PDF]
Osteoporotic changes start in cancellous bone due to the underlying pathophysiology. Consequently, the metaphyses are at a higher risk of "osteoporotic” fracture than the diaphysis. Furthermore, implant purchase to fix these fractures is also affected by
Curtis, R. +4 more
core
OBJETIVO: Medir o volume ocupado pelos dispositivos de fixação interna mais difundidos para o tratamento das fraturas de colo femoral, usando como aproximação os primeiros 30, 40 e 50mm de cada parafuso. O estudo visa observar qual desses implantes causa
Daniel Lauxen Junior +9 more
doaj
Purpose This paper investigates the biomechanical benefits of using hybrid constructs that combine cannulated screws with tension band wiring (TBW) cerclage compared to cannulated screws with anterior Variable Angle locking neutralisation plates (VA LNP).
Majd Tarabichi +6 more
doaj +1 more source