Results 31 to 40 of about 56,740 (149)
Parity meter for charge qubits: an efficient quantum entangler [PDF]
We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated ...
Beenakker, C. W. J. +3 more
core +4 more sources
Device for determining the accuracy of the flare on a flared tube [PDF]
Capacitance measuring device for determining flare accuracy on tapered ...
Griffin, F. D.
core +1 more source
Response analyzers for sensors Patent [PDF]
Response analyzing apparatus for liquid vapor interface sensor of sloshing rocket ...
Bynum, B. G., Talley, D. H.
core +1 more source
RTM production monitoring of the A380 hinge arm droop nose mechanism: a multi-sensor approach [PDF]
his research presents a case study of production monitoring on an aerospace composite component: the hinge arm of the droop nose mechanism on the Airbus A380 wing leading edge.
Chiesura, Gabriele +7 more
core +2 more sources
Electrical properties of dried quinces utilization [PDF]
The aim of this study was to measure the electrical properties of dried quinces. Faculty of Agriculture of University in Novi Sad had provided the samples of dried quinces (Cydonia Oblonga Mill.) in the frame of a bilateral project. Electrical resistance,
Kertész Ákos +2 more
doaj
We have investigated the effects of X-ray irradiation to doses of 0, 200 Gy, 20 kGy, 2 MGy, and 20 MGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050C. The SiPMs were irradiated without applied bias voltage.
Garutti, Erika +3 more
core +1 more source
Tackling Challenges in Seebeck Coefficient Measurement of Ultra-High Resistance Samples with an AC Technique [PDF]
Seebeck coefficient is a widely studied semiconductor property. Conventional Seebeck coefficient measurements are based on DC voltage measurement. Normally this is performed on samples with moderate resistances (e.g., below a few MΩ level).
Pan, Z +5 more
core +2 more sources
This paper presents the change in the volt-farad characteristics of the Al/SiO2/n-Si structure irradiated with helium ions with the energy of 5 MeV in the frequencies of 1, 10, 100, and 1000 kHz.
V. Q. Nha +4 more
doaj +1 more source
An ultra-low-cost RCL meter, aimed at IoT applications, was developed, and was used to measure electrical components based on standard techniques without the need of additional electronics beyond the AVR® micro-controller hardware itself and high-level ...
Pedro M. C. Inácio +2 more
doaj +1 more source
Identifikasi Karakteristik Kapasitansi Daging Ayam Tiren Dan Daging Ayam Normal [PDF]
Identification of tiren chicken and normal chicken capacitance characteristic was done to know the characteristic of both of them based on their capacitance and to know whether the characteristic is different or same from both of them.
Atmaja, A. W. (Anggara) +3 more
core

