Results 61 to 70 of about 69,873 (298)

Automatic frequency control of voltage-controlled oscillators [PDF]

open access: yes, 1969
Optical-capacitive coupling is used for isolation of control voltages, such as the high-voltage level of a klystron control electrode that is not referenced to ground, to serve as error voltages referenced to system ground so that the magnitude and sense
Kolbly, R. B.
core   +1 more source

A New Threshold Switching Device With Tunable Negative Differential Resistance Based on ErMnO3 Polymorphs

open access: yesAdvanced Functional Materials, EarlyView.
Polymorph engineering in ErMnO3 enables low‐voltage, forming‐free threshold switching with tunable negative differential resistance. Conducting orthorhombic regions embedded in an insulating hexagonal matrix provide controlled Joule‐heating‐enhanced Poole–Frenkel transport. The hexagonal phase prevents excessive heating and breakdown.
Rong Wu   +8 more
wiley   +1 more source

High Energy Density Asymmetric Aqueous Supercapacitor Based on a 2D Manganese Carbide as a Positive Electrode

open access: yesAdvanced Functional Materials, EarlyView.
A circular route, involving upcycling of waste surgical masks, affords a Mn‐based layered carbide with porosity, redox activity and low work function. These features enable its effective operation as positive supercapacitor electrode in an aqueous asymmetric supercapacitor delivering 213 Wh L−1 energy density.
Debabrata Nandi   +7 more
wiley   +1 more source

Probing two-qubit capacitive interactions beyond bilinear regime using dual Hamiltonian parameter estimations

open access: yesnpj Quantum Information, 2023
We report the simultaneous operation and two-qubit-coupling measurement of a pair of two-electron spin qubits, actively decoupled from quasi-static nuclear noise in a GaAs quadruple quantum dot array. Coherent Rabi oscillations of both qubits (decay time
Jonginn Yun   +10 more
doaj   +1 more source

Electromagnetic coupling simulagions for a magnetic induction sensor for sleep monitoring [PDF]

open access: yes, 2014
Magnetic induction (MI) method has been extensively used in non-destructive testing of materials. In biomedical applications, it attracted lots of attention for the contact-less advantages it provides.
Mahdavi, Hadiseh   +1 more
core  

Coulomb Blockade and Kondo Effect in a Quantum Hall Antidot

open access: yes, 2003
We propose a general capacitive model for an antidot, which has two localized edge states with different spins in the quantum Hall regime. The capacitive coupling of localized excess charges, which are generated around the antidot due to magnetic flux ...
A. C. Hewson   +9 more
core   +1 more source

Negativity of the excess noise in a quantum wire capacitively coupled to a gate [PDF]

open access: yes, 2007
The electrical current noise of a quantum wire is expected to increase with increasing applied voltage. We show that this intuition can be wrong. Specifically, we consider a single channel quantum wire with impurities and with a capacitive coupling to ...
A. O. Gogolin   +15 more
core   +2 more sources

Overcoming Debye Length Limitations in Electrolyte‐Gated Transistor Biosensors Using Nanoscale‐Grooved Oxide Semiconductors Fabricated by Thermal Nanoimprint Lithography

open access: yesAdvanced Functional Materials, EarlyView.
Nanoscale‐grooved indium gallium oxide (IGO) semiconductors, patterned via thermal nanoimprint lithography (NIL) using CD/DVD templates, are integrated into electrolyte‐gated transistor biosensors to overcome Debye length limitations. Precisely engineered concave–convex nanostructures modulate local electrostatic potentials, extend the effective Debye ...
Jong Yu Song   +5 more
wiley   +1 more source

Accuracy and Reliability of Switching Transients Measurement with Open-Air Capacitive Sensors

open access: yesEnergies, 2019
Contactless capacitive (open-air) sensors are applied to monitor overvoltages near overhead line terminations at a substation or at the transition from underground cables to overhead lines.
Fani Barakou   +2 more
doaj   +1 more source

Carbon Contacts to Proteins Enable Robust, Biocompatible Electronic Junctions with Near‐Activation‐less Conduction Down to 10 K

open access: yesAdvanced Functional Materials, EarlyView.
A robust solid‐state protein junction with a semi‐transparent eC/Au electrode allows photoexcitation of the bacterio‐rhodopsin, bR layer, to isomerize the bR retinal. The resulting photo‐response shows the protein is functional in the solid‐state junction.
Shailendra K. Saxena   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy