Ion‐Reconfigurable “N”‐Shaped Antiambipolar Behavior in Organic Electrochemical Transistors

open access: yesAdvanced Materials, EarlyView.
A unique N‐shaped negative differential transconductance (NDT) characteristics is demonstrated in single‐polymer organic electrochemical transistors through a sequential doping–redox–doping process driven by iodide ions. This redox‐driven mechanism enables low‐voltage, ion‐controlled reconfigurability and tunable current modulation, allowing seamless ...
Debdatta Panigrahi   +11 more
wiley   +1 more source

Driver Position Measured Based on Textile Capacitive Sensor Array

open access: yesProceedings
A woven textile capacitive sensor array fully integrated on a car seat is presented to detect the driver’s position. The sensor array consists of two planar interdigital capacitive sensors located on the base and the backrest of the seat.
Marc Martínez-Estrada   +2 more
doaj   +1 more source

Energetic Offset in Organic Solar Cells‐ Importance, Confusion and Outlook

open access: yesAdvanced Materials, EarlyView.
Energetic offsets in organic solar cells (OSCs) remain a subject of debate due to measurement‐ and lab‐dependent discrepancies. This Perspective clarifies the physical origins of these variations and identifies temperature‐dependent electro‐optical methods as a reliable approach to obtain consistent offset values.
Nakul Jain   +5 more
wiley   +1 more source

Ultrafast Vertical Organic Electrochemical Transistors With Ion‐Permeable Conductive Polymer Top Electrodes

open access: yesAdvanced Materials, EarlyView.
Vertical organic electrochemical transistors (vOECTs) are limited in speed by ion‐impermeable metal electrodes that slow ion injection. Using ion‐permeable PBFDO top electrodes allows direct vertical ion injection into BBL channels, achieving high current densities (>400 A cm−2), large on/off ratios (>106), and ultrafast switching in 28 µs. This sets a
Han‐Yan Wu   +14 more
wiley   +1 more source

Design and testing of a thick-film dual-modality sensor for composition measurements in heterogeneous mixtures

open access: yes, 2005
The current paper focuses on design and laboratory evaluation of a dual-modality sensor, developed for the needs of oil and gas extraction industry to measure the composition of heterogeneous mixtures in harsh conditions.
Hale, Jack   +4 more
core   +1 more source

A Redundant-Sensing-Based Six-Axis Force/Torque Sensor Enabling Compactness and High Sensitivity

open access: yesSensors
Capacitive sensors are widely adopted in compact robotic systems due to their simple structure, ease of fabrication, and scalability for miniaturized designs.
Seung Yeon Lee   +6 more
doaj   +1 more source

Neuromorphic Electronics for Intelligence Everywhere: Emerging Devices, Flexible Platforms, and Scalable System Architectures

open access: yesAdvanced Materials, EarlyView.
The perspective presents an integrated view of neuromorphic technologies, from device physics to real‐time applicability, while highlighting the necessity of full‐stack co‐optimization. By outlining practical hardware‐level strategies to exploit device behavior and mitigate non‐idealities, it shows pathways for building efficient, scalable, and ...
Kapil Bhardwaj   +8 more
wiley   +1 more source

Practical in-situ calibration method for the non-linear output from a low cost eddy current sensor [PDF]

open access: yes, 2012
Increasing demand on manufacturing industry to produce tighter tolerance parts at a consistent rate means it is necessary to gain a greater understanding of machine tool capabilities, error sources and factors affecting asset availability.
Longstaff, Andrew P.   +5 more
core   +3 more sources

Monolithic 3D‐Integrated All‐Solid Ion‐Gated Carbon Nanotube Transistors With Tunable Ionic Conductance for Multi‐Timescale Reservoir Computing

open access: yesAdvanced Materials, EarlyView.
A dual‐timescale reservoir based on monolithically 3D (M3D)‐integrated CNT solid ion‐gated transistors is demonstrated. Tunable ionic dynamics and pulse‐engineered operation enable linear and symmetric synaptic updates. The M3D‐integrated array achieves robust temporal encoding and accurate classification of moving MNIST sequences, highlighting its ...
Haksoon Jung   +9 more
wiley   +1 more source

A novel calibration method for PD measurement in power cables and joints using capacitive couplers

open access: yes, 2004
Partial discharge (PD) measurements are universally accepted as a technique giving some indication of the state of the insulation in high voltage apparatus.
Xu, Y, Zhong, L, Chen, G