Results 81 to 90 of about 2,304,647 (255)

An Electrowetting Pump

open access: yesAdvanced Functional Materials, EarlyView.
A tubular electrowetting pump moves alternating droplets through a millimeter‐wide channel in discrete, reversible steps, functioning as a fluidic stepper motor. With no moving parts and electrodes insulated from the liquid, it delivers silent, accurate flow. Flexibility allows the pump to be woven directly into textiles for wearable, medical, and soft‐
Robert Hennig, Herbert Shea
wiley   +1 more source

Wearable Kirigami‐Apertured Capacitive Sensors for Continuous Cardiac Volumetric Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A wearable kirigami‐apertured carbon nanotube‐paper composite (K‐CPC) capacitive sensor enables cardiac volumetric monitoring. The kirigami process creates a central aperture with cantilevered fibers that confine the electric field, enhancing both sensitivity and lateral resolution.
Yu‐Jen Cheng   +4 more
wiley   +1 more source

Design and Characteristic Analysis of Cross-Capacitance Fuel-Level Sensor

open access: yesSensors, 2018
A cross-capacitance liquid level sensor is based on the principle of cross capacitance. This study designed a new single-tube cross-capacitance fuel-level sensor.
Jing Yu, Hang Yu, Dongsheng Li
doaj   +1 more source

Design and Characterization of a Two‐Dimensional Soft Array Based on Cooperative Dielectric Elastomer Actuators

open access: yesAdvanced Functional Materials, EarlyView.
A fully polymeric two‐dimensional array of Dielectric Elastomers enables self‐sensing, cooperative actuation, and large‐stroke operation in a DE‐based autonomous conveyor. Based only on voltage and current measurements at actuator level, the system detects the presence of a ball and subsequently drives it toward a target position.
Saverio Addario   +6 more
wiley   +1 more source

A flexible, ultra-highly sensitive and stable capacitive pressure sensor with convex microarrays for motion and health monitoring

open access: yes, 2020
Recently, flexible sensors endowed with high sensitivity, low detection limit, broad working pressure range and fast response have aroused widespread concern owing to their vital role in the development of wearable artificial devices, human-machine ...
Yaoxu Xiong   +6 more
semanticscholar   +1 more source

Memristive‐Gated RC‐Delay Synaptic Transistors for Time‐Encoded Analog in‐Memory Computing

open access: yesAdvanced Functional Materials, EarlyView.
A Memristive‐Gated Transistor for Time‐Encoded Analog In‐Memory Computing — By exploiting the RC delay of a self‐rectifying interface‐type memristor, nonlinear I–V distortion is structurally bypassed, enabling 3‐bit nonvolatile memory, spike‐timing‐based analog encoding, and hardware‐calibrated reservoir‐computing validation within a unified device ...
Yun‐Seo Shin   +7 more
wiley   +1 more source

Design of instantaneous liquid film thickness measurement system for conductive or non-conductive fluid with high viscosity

open access: yesAIP Advances, 2017
In the paper, a new capacitive sensor with a dielectric film coating was designed to measure the thickness of the liquid film on a flat surface. The measured medium can be conductive or non-conductive fluid with high viscosity such as silicone oil, syrup,
Yongxin Yu   +4 more
doaj   +1 more source

Balancing Hydrophobicity and Hydrophilicity: Dual Filler‐Engineered Proton Exchange Membranes for Durable, High‐Power Fuel Cells

open access: yesAdvanced Functional Materials, EarlyView.
Polarity‐matched Zr–MOFs program Nafion's nanoscale morphology during solution casting. Hydrophilic UiO‐66 preserves hydrated pathways, while hydrophobic UiO‐67 increases the proton hopping sites by densifying ionic clusters. Combining both fillers yields a membrane that delivers 176 mS cm−1 conductivity, reaches 1.46 W cm−2 under 200 kPa, and triples ...
Yonghwi Cho   +13 more
wiley   +1 more source

Dual‐Layer Conducting and Redox Polymer Bioanodes for Synergistic Enhancement of Microbial Extracellular Electron Transfer

open access: yesAdvanced Functional Materials, EarlyView.
A hybrid PEDOT/Fc‐LPEI conducting/redox polymer bioanode synergistically improves microbial extracellular electron transfer (EET) in Shewanella oneidensis MR‐1. The dual‐layer interface delivers 18‐fold higher current output and 27‐fold greater charge collected than bare carbon felt, highlighting an effective strategy for high‐performance ...
Shenghan Gu   +4 more
wiley   +1 more source

Kinetics‐Controlled Architecture of Binder‐Free Organic Electrodes for Enhanced Ion Transport

open access: yesAdvanced Functional Materials, EarlyView.
Pulse reverse electrodeposition controls nucleation and growth to create hierarchically porous Py‐derived oligomeric electrodes with enhanced ionic accessibility and reduced transport resistance. The resulting binder‐free architectures translate these transport advantages into practical sodium‐storage functionality.
Satendra Kumar   +1 more
wiley   +1 more source

Home - About - Disclaimer - Privacy