Results 61 to 70 of about 325,777 (335)
Thrombolytic proteins profiling: High‐throughput activity, selectivity, and resistance assays
We present optimized biochemical protocols for evaluating thrombolytic proteins, enabling rapid and robust screening of enzymatic activity, inhibition resistance, and fibrin affinity, stimulation, and selectivity. The outcome translates to key clinical indicators such as biological half‐life and bleeding risk. These assays streamline the development of
Martin Toul +3 more
wiley +1 more source
Receiving nano-carbon, in particular, graphitic films of nanometer thickness and research of their properties is one of current problems of the modern science.
K.M. Makhanov +4 more
doaj
Electrometer has automatic zero bias control [PDF]
Zero biasing circuit in a vibrating reed type electrometer counterbalances residual potential. It charges a capacitor to the residual potential and connects that capacitor in series with the vibrating reed so that the voltages cancel.
core +1 more source
Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors [PDF]
This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electrical LC tank resonant
Chen, Po-Jui +4 more
core +1 more source
A Single-Objective Modulated Model Predictive Control for a Multilevel Flying Capacitor Converter in a DC Microgrid [PDF]
Vijesh Jayan, Amer M. Y. M. Ghias
openalex +1 more source
Overview of molecular signatures of senescence and associated resources: pros and cons
Cells can enter a stress response state termed cellular senescence that is involved in various diseases and aging. Detecting these cells is challenging due to the lack of universal biomarkers. This review presents the current state of senescence identification, from biomarkers to molecular signatures, compares tools and approaches, and highlights ...
Orestis A. Ntintas +6 more
wiley +1 more source
Feedback integrator with grounded capacitor Patent [PDF]
Feedback integrating circuit with grounded capacitor for signal ...
Deboo, G. J.
core +1 more source
RoboMic is an automated confocal microscopy pipeline for high‐throughput functional imaging in living cells. Demonstrated with fluorescence recovery after photobleaching (FRAP), it integrates AI‐driven nuclear segmentation, ROI selection, bleaching, and analysis.
Selçuk Yavuz +6 more
wiley +1 more source
Cascaded transformerless DC-DC voltage amplifier with optically isolated switching devices [PDF]
A very high voltage amplifier is provided in which plural cascaded banks of capacitors are switched by optically isolated control switches so as to be charged in parallel from the preceding stage or capacitor bank and to discharge in series to the ...
Sridharan, Govind
core +1 more source
Raman‐based label‐free microscopic analysis of the pancreas in living zebrafish larvae
Forward stimulated Raman scattering (F‐SRS) and epi coherent anti‐Stokes Raman scattering (E‐CARS) allow label‐free discrimination of distinct subcellular structures in the pancreas of living zebrafish larvae. Given the straightforward applicability, we anticipate broad implementation of Raman microscopy in other organs and across various biomedical ...
Noura Faraj +3 more
wiley +1 more source

