Results 21 to 30 of about 18,197 (205)
An image-based approach for the estimation of arterial local stiffness in vivo
The analysis of mechanobiology of arterial tissues remains an important topic of research for cardiovascular pathologies evaluation. In the current state of the art, the gold standard to characterize the tissue mechanical behavior is represented by ...
Simona Celi +9 more
doaj +1 more source
Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries
Background Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-
Tan Huan +4 more
doaj +1 more source
Variability introduced by the operator in processing myocardial Gated-SPECT studies
Introduction – Gated - Single Photon Emission Computed Tomography (SPECT) is one of cardiac imaging techniques with more development over last decades. For image analysis, the use of quantification software leads to increased reproducibility and accuracy
Marta O. Antunes +2 more
doaj +1 more source
Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating
Background Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies.
Fabian Kording +11 more
doaj +1 more source
The impact of cardiopulmonary hemodynamic factors in volumetry for pulmonary nodule management
Background The acceptance of coronary CT angiogram (CCTA) scans in the management of stable angina has led to an exponential increase in studies performed and reported incidental findings, including pulmonary nodules (PN).
Erique Guedes Pinto +6 more
doaj +1 more source
Delivery of DNA‐encoded vaccines and proteins in mice using cutaneous suction‐mediated transfection
Cutaneous suction‐mediated transfection in mice for delivery of DNA‐encoded vaccines and proteins. A critical limitation of DNA vaccines and other therapeutics is transfection in vivo to produce the encoded antigens or therapeutic proteins. Cutaneous suction‐based methods have demonstrated effectiveness in many animal models and have been successfully ...
Emran O. Lallow +12 more
wiley +1 more source
Background Recent studies have shown that the right ventricular (RV) quantitative analysis in myocardial perfusion imaging (MPI) SPECT can be beneficial in the diagnosis of many cardiopulmonary diseases.
Seyed Mohammad Entezarmahdi +5 more
doaj +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Advances in Sustainable and Wearable Textile Based Soft Robotics
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas +6 more
wiley +1 more source
Radiation dose in cardiac CT for preoperative diagnosis of children with congenital heart disease
Background One of the most common congenital conditions detected globally, congenital heart diseases, and CT techniques provide a high-quality and thorough presentation of heart anatomy, thoracic vasculature, and extracardiac structures, and hence, it is
Samreen Shahid +4 more
doaj +1 more source

