Results 41 to 50 of about 8,541,483 (254)
Inappropriate Defibrillator Shocks due to Mechanical Inference from an Investigational Device
Cardiac contractility modulation (CCM) is an investigational device-based therapy to enhance ventricular contractility in systolic heart failure patients who are not candidates for cardiac resynchronization therapy (CRT) owing to the absence of wide QRS ...
Ying chi Yang +2 more
doaj +1 more source
An unusual case of fungal ball on implantable cardioverter defibrillator wire and literature review
Cardiac Implantable Electronic Device (CIED) includes pacemakers and implantable cardioverter defibrillators (ICD). The device infection is classified into pocket and systemic infection.
Hiba Rauf +6 more
doaj +1 more source
Cardiac implantable electronic device infections [PDF]
With increasing rates of device implantation, there is an increased recognition of device infection. We conducted a retrospective observational study in a tertiary care center in Lebanon, with data collected from medical records of patients presenting ...
Refaat, Marwan M. +7 more
core +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Biodegradable and Biocompatible Functional Polymers for Biomedical Applications
Biodegradable and biocompatible functional polymers integrate electrical, mechanical, and stimuli‐responsive functionalities while enabling programmed degradation under physiological conditions. This review introduces recent advances in conductive, shape‐memory, self‐healing, photocurable, and adhesive polymer systems, emphasizing material design ...
Won Bae Han +5 more
wiley +1 more source
Rare enough ? Cardiac Device‐related pocket Infection due to Mycobacterium fortuitum
Nontuberculous mycobacteria are rare causes of cardiac implantable electronic device (CIED)‐related infections and may lead to device‐related endocarditis, so preventing them is key. We present a case of CIED‐related pocket infection due to Mycobacterium
Reshma Golamari +6 more
doaj +1 more source
Background Sustained atrial high‐rate episodes (SAHREs) among individuals with a cardiac implantable electronic device are associated with an increased risk of adverse outcomes.
Yan‐Guang Li +4 more
doaj +1 more source
Under NIR irradiation, PTCPP generates ROS to eliminate MRSA biofilms and promote M1 macrophage polarization for phagocytosis. After bacterial clearance, the material is phagocytosed by macrophages, shifting their polarization to M2 phenotype via metabolic reprogramming, which synergistically enhances anti‐infection therapy and wound healing.
Honghao Ma +13 more
wiley +1 more source
Discontinuation of cardiac implantable electronic device therapy after transvenous lead extraction [PDF]
Background: Patients with cardiac implantable electronic devices (CIEDs) may no longer be eligible for continued therapy.Aims: The study aimed to assess the circumstances under which CIED reimplantation may not be necessary after transvenous lead ...
Kutarski, Andrzej; Department of Cardiology, Medical University, Lublin, Poland +5 more
core +2 more sources
Optical Detection of Cellular Signals at Material Interfaces
Emerging functional materials are transforming optical detection of cellular signals. This review highlights optical techniques that exploit the unique optical properties of diverse materials to detect and quantify cellular electrical, chemical, and mechanical signals, and discusses key opportunities and challenges.
Xuchen Ren +5 more
wiley +1 more source

