Results 71 to 80 of about 15,097 (199)
Cardiac Implantable Electronic Devices [PDF]
Thakur R., Natale A.
openaire +3 more sources
Um monitor do estado de carga da bateria de dispositivos eletrônicos implantáveis [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia ElétricaThis work proposes a system, of very low power consumption, able to monitor the remaining charge of the batteries used in
Machado, Márcio Bender
core
Background: Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices.
Olen, Melissa M +5 more
core +1 more source
Microbiology of Cardiac Implantable Electronic Device Infections
This study reports a high-volume tertiary care center experience with the microbiology of cardiac implantable electronic devices (CIED) infections with assessment of temporal trends and profiles of late versus early infections.The rates of CIED infections have been increasing. With changing demographics, patient and device characteristics, prophylactic
Ayman A, Hussein +9 more
openaire +2 more sources
Key Clinical Message Venous spasm is an important reason for complicated or failed implantations of cardiac implantable electronic devices. Prevention or risk reduction of venous spasm during cardiac implantable electronic device implantation may be ...
Amelie Venet +4 more
doaj +1 more source
This survey analyses some details of follow-up of patients with cardiac implantable electronic devices (CIEDs) in 40 centresthe members of the European Heart Rhythm Association (EHRA) research network.
Marinskis, Germanas +20 more
core +1 more source
Cardiac implantable electronic device infection: Does the device need to be extracted?
Background Cardiac implantable electronic devices (CIED) have become a common treatment modality in clinical practice. The increase in utilization of these devices has been associated with an increase in infection rates.
Sandhya Nagarakanti +2 more
doaj +1 more source
Incidence and risk factors of pacemaker pocket infection – an observational study
This retrospective, hospital-based observational study was aimed to examine the indications for PPM implantation, risk factors, demographics, and microbiological profiles of PPM infections (PPMI).
Manish Kapoor +4 more
doaj +1 more source
Critical appraisal of cardiac implantable electronic devices: complications and management
Luigi Padeletti1, Giosuè Mascioli2, Alessandro Paoletti Perini1, Gino Grifoni1, Laura Perrotta1, Procolo Marchese3, Luca Bontempi3, Antonio Curnis31Istituto di Clinica Medica e Cardiologia, Università degli Studi di Firenze, Italia;
Perrotta L +7 more
core
Clinical use of antibacterial mesh envelopes in cardiovascular electronic device implantations
David S Hirsh,1,2 Heather L Bloom1,2 1Department of Cardiovascular Medicine, School of Medicine, Emory University, Atlanta, GA, USA; 2Department of Cardiovascular Medicine, Atlanta Veterans Affairs Medical Center, Decatur, GA, USA Abstract ...
Hirsh DS, Bloom HL
doaj