Results 201 to 210 of about 362,342 (293)

Impact of CYP2C19 Genotype Variants on PCSK9 Inhibitor Efficacy in Lipid‐Lowering Among Patients With Symptomatic Intracranial Atherosclerotic Stenosis

open access: yesLipids, EarlyView.
ABSTRACT Ischemic stroke is frequently associated with symptomatic intracranial atherosclerotic stenosis (sICAS), is a leading cause of global disability and mortality. Current guidelines recommend dual antiplatelet and intensive statin therapies. Proprotein convertase subtilisin 9/kexin type 9 (PCSK9) inhibitors have emerged as a potent lipid‐lowering
Chao Zhao   +5 more
wiley   +1 more source

Identification and characterization of tryptophan metabolism-related genes in carotid artery plaques. [PDF]

open access: yesPLoS One
Jia X   +8 more
europepmc   +1 more source

A paraoxonase gene polymorphism, PON 1 (55), as an independent risk factor for increased carotid intima-media tickness in middle-aged women. [PDF]

open access: yes, 2003
DE MICHELE M   +10 more
core  

Ultrafast Blood T1 Measurement Using Golden Angle Rotated Spiral k‐t Sparse Parallel Imaging (GASSP): Evaluations in Both Pre‐ and Post‐Contrast Conditions

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Blood T1 is a key parameter for hemodynamic quantification in both non‐contrast‐ and contrast‐enhanced imaging. Individual vessel T1 has been measured using a modified Look–Locker scheme with multi‐shot EPI or FLASH in high spatial resolution, requiring ∼1 min.
Zechen Xu, Feng Xu, Qin Qin, Dan Zhu
wiley   +1 more source

External carotid steal and lateral medullary infarction - is there a pathogenetic connection? [PDF]

open access: yes, 1983
A Wallenberg   +18 more
core   +1 more source

Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a protocol for simultaneous volumetric T1 and T2 mapping with blood‐ and fat‐suppression, and apply it to patients with abdominal aortic aneurysms (AAA) to assess tissue characteristics. Methods A spoiled gradient echo (SPGR) variable flip angle (VFA) acquisition was modified with preparation modules to suppress
Wilhelm Stehling   +7 more
wiley   +1 more source

Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling (M2‐PCASL) Sequence: A Test–Retest Reliability Study

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose We aim to assess the reliability of cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) obtained simultaneously from a novel multi‐band pseudo‐continuous arterial spin labeling (M2‐PCASL) sequence and hypercapnic gas challenge, to examine factors influencing CBF variability, and to evaluate the impact of carbon dioxide (CO2)
Jody Todd   +3 more
wiley   +1 more source

Cost-Effectiveness of Risk-Based Screening for Asymptomatic Carotid Artery Stenosis. [PDF]

open access: yesMDM Policy Pract
Zhu J   +8 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy