Results 171 to 180 of about 730,182 (230)

Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1956-1971, October 2026.
ABSTRACT Aims Purpose: Dictionary matching is a standard tool in quantitative MRI (qMRI), but typically lacks uncertainty quantification (UQ). This is critical when advanced reconstructions (e.g., compressed sensing, deep learning) introduce complex‐valued, spatially varying, and temporally correlated noise that violates standard assumptions of ...
Brian Toner   +7 more
wiley   +1 more source

Short Echo‐Time Spiral MRSI Versus Single‐Voxel Spectroscopy in the Human Brain at 3 Tesla With Semi‐LASER Localization

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1524-1533, October 2026.
ABSTRACT Purpose Magnetic resonance spectroscopy techniques are widely used to non‐invasively study brain metabolism. Despite advances in magnetic resonance spectroscopic imaging (MRSI), there is a notable absence of research on comparing fast non‐Cartesian MRSI with single‐voxel spectroscopy (SVS), limiting our understanding of its performance and ...
Young Woo Park   +3 more
wiley   +1 more source

Simultaneous T2, T2*, and R2′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE‐EPI MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1872-1892, October 2026.
ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T2, T2*, and R2′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T2 and T2* information.
Jose Raul Velasquez Vides   +16 more
wiley   +1 more source

Accurate and affordable cobot calibration without external measurement devices. [PDF]

open access: yesCommun Eng
Franzese G   +4 more
europepmc   +1 more source

Laterally Oscillating Trajectory for Undersampling Slices: LOTUS

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1682-1695, October 2026.
ABSTRACT Purpose While spiral sampling offers SNR advantages for diffusion MRI, its acceleration with simultaneous multislice remains relatively unexplored. This study introduces Laterally Oscillating Trajectory for Undersampling Slices (LOTUS), which is a 3D spiral‐like k‐space trajectory that aims to minimize g‐factor via controlled incoherent ...
Mayuri Sothynathan   +2 more
wiley   +1 more source

Arc‐ZTE: Continuously‐Slewed Zero‐TE Imaging With Incoherent Temporal Sampling for Near‐Silent Dynamic MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1726-1740, October 2026.
ABSTRACT Purpose To enable flexible dynamic and DCE MRI with low acoustic noise and high spatiotemporal resolution using zero echo time (ZTE) imaging. Methods This work proposes Arc‐ZTE, a technique in which the readout gradients of ZTE are continuously‐slewed to form arcs in k‐space that are sequentially rotated to yield an incoherent trajectory ...
Shreya Ramachandran   +5 more
wiley   +1 more source

The Iseult Coil, a Hybrid RF Coil for the First Human Brain Images at 11.7 T: Receive Performance Comparison With a Twin Coil at 7 T

open access: yesNMR in Biomedicine, Volume 39, Issue 10, October 2026.
Our 8‐Tx/32‐Rx coil is based on two rows of transceiver microstrips intertwined with receive‐only loops. Comparison of the intrinsic SNR at 7 and 11.7 T leads to a 2.2 ratio for the human brain, and 2.75 for a 16‐cm agar sphere, translating into α = 1.5 and 1.95 in the B0α$$ {B}_0^{\alpha } $$‐SNR model, respectively.
Alexis Amadon   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy