Results 191 to 200 of about 215,493 (276)

Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1956-1971, October 2026.
ABSTRACT Aims Purpose: Dictionary matching is a standard tool in quantitative MRI (qMRI), but typically lacks uncertainty quantification (UQ). This is critical when advanced reconstructions (e.g., compressed sensing, deep learning) introduce complex‐valued, spatially varying, and temporally correlated noise that violates standard assumptions of ...
Brian Toner   +7 more
wiley   +1 more source

Simultaneous T2, T2*, and R2′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE‐EPI MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1872-1892, October 2026.
ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T2, T2*, and R2′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T2 and T2* information.
Jose Raul Velasquez Vides   +16 more
wiley   +1 more source

Numerical Integration of Slater Basis Functions Over Prolate Spheroidal Grids. [PDF]

open access: yesJ Comput Chem
Stark A   +5 more
europepmc   +1 more source

Arc‐ZTE: Continuously‐Slewed Zero‐TE Imaging With Incoherent Temporal Sampling for Near‐Silent Dynamic MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1726-1740, October 2026.
ABSTRACT Purpose To enable flexible dynamic and DCE MRI with low acoustic noise and high spatiotemporal resolution using zero echo time (ZTE) imaging. Methods This work proposes Arc‐ZTE, a technique in which the readout gradients of ZTE are continuously‐slewed to form arcs in k‐space that are sequentially rotated to yield an incoherent trajectory ...
Shreya Ramachandran   +5 more
wiley   +1 more source

Forecasting Patient-Specific Abdominal Aortic Aneurysm Geometry with Mixed-Effects Models. [PDF]

open access: yesDiagnostics (Basel)
Restrepo JC   +7 more
europepmc   +1 more source

The Iseult Coil, a Hybrid RF Coil for the First Human Brain Images at 11.7 T: Receive Performance Comparison With a Twin Coil at 7 T

open access: yesNMR in Biomedicine, Volume 39, Issue 10, October 2026.
Our 8‐Tx/32‐Rx coil is based on two rows of transceiver microstrips intertwined with receive‐only loops. Comparison of the intrinsic SNR at 7 and 11.7 T leads to a 2.2 ratio for the human brain, and 2.75 for a 16‐cm agar sphere, translating into α = 1.5 and 1.95 in the B0α$$ {B}_0^{\alpha } $$‐SNR model, respectively.
Alexis Amadon   +8 more
wiley   +1 more source

EasyGrid: a versatile platform for automated cryo-EM sample preparation and quality control. [PDF]

open access: yesNat Methods
Gemin O   +29 more
europepmc   +1 more source

Analysis of Eigenvalue Clustering Leads to Optimal Scaling in Numerical Radiative Transfer

open access: yesNumerical Linear Algebra with Applications, Volume 33, Issue 5, October 2026.
ABSTRACT We consider a multidimensional polychromatic radiative transfer (RT) problem, accounting for scattering processes in a general form, that is, anisotropic (dipole) scattering with partial frequency redistribution. Given a discrete ordinates (SN$$ {S}_N $$) discretization, we report the corresponding matrix structures, depending on the model and
Pietro Benedusi   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy