Results 61 to 70 of about 55,584 (294)

Effects of tip clearance on overall performance of transonic fan stage with and without casing treatment [PDF]

open access: yes
The overall performance of a transonic fan stage is presented for various tip clearances, with and without casing treatment. The stage was tested with a solid casing, and with open skewed slots and closed skewed slots in the casing over the rotor blade ...
Moore, R. D., Osborn, W. M.
core   +1 more source

Parent‐to‐Child Information Disclosure in Pediatric Oncology

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Despite professional consensus regarding the importance of open communication with pediatric cancer patients about their disease, actual practice patterns of disclosure are understudied. Extant literature suggests a significant proportion of children are not told about their diagnosis/prognosis, which is purported to negatively ...
Rachel A. Kentor   +12 more
wiley   +1 more source

A Review of Stall Detection in Subsonic Axial Compressors

open access: yesMachines
Stall events in axial compressor systems have been a limiting factor for efficiency of such systems and a source of safety concerns. The detection of the onset of stall, and in many cases the precursor of the onset of stall, have been of interest in the ...
Kellie N. Wilson   +6 more
doaj   +1 more source

Effect of casing treatment on performance of an inlet stage for a transonic multistage compressor [PDF]

open access: yes
An inlet stage of a transonic compressor was tested with three rotor tip casing treatment configurations: blade angle slots, circumferential grooves, and axial skewed slots.
Lewis, G. W., Jr.   +2 more
core   +1 more source

Prolonged Corrected QT Interval as an Early Electrocardiographic Marker of Cyclophosphamide‐Induced Cardiotoxicity in Pediatric Hematology and Oncology Patients

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Cyclophosphamide (CY) is associated with potentially fatal cardiotoxicity, yet no electrocardiographic indices have been established for early detection of CY‐induced cardiomyopathy. This study aimed to determine whether corrected QT interval (QTc) prolongation can predict early onset of CY‐related cardiac dysfunction in pediatric ...
Junpei Kawamura   +5 more
wiley   +1 more source

Performance of two-stage fan having low-aspect-ratio first-stage rotor blading [PDF]

open access: yes
The NASA two stage fan was tested with a low aspect ratio first stage rotor having no midspan dampers. At design speed the fan achieved an adiabatic design efficiency of 0.846, and peak efficiencies for the first stage and rotor of 0.870 and 0.906 ...
Cunnan, W. S.   +2 more
core   +1 more source

Ground-water resources of Collier County, Florida [PDF]

open access: yes, 1962
The Biscayne Aquifer is the principal source of water for the heavily populated area in the vicinity of West Palm Beach and Miami. The publication of this data is timely and will assist in the intelligent development of the water resources of the area.
McCoy, H. J.
core  

Predicting Chronicity in Children and Adolescents With Newly Diagnosed Immune Thrombocytopenia at the Timepoint of Diagnosis Using Machine Learning‐Based Approaches

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Objectives To identify predictors of chronic ITP (cITP) and to develop a model based on several machine learning (ML) methods to estimate the individual risk of chronicity at the timepoint of diagnosis. Methods We analyzed a longitudinal cohort of 944 children enrolled in the Intercontinental Cooperative immune thrombocytopenia (ITP) Study ...
Severin Kasser   +6 more
wiley   +1 more source

Influence of slotted casing treatment with surface roughness and dimples on the performance of an axial flow fan

open access: yesCogent Engineering
A numerical analysis is conducted to assess the impact of slotted casing treatments, dimples, and surface roughness on the performance of an axial flow fan. Five configurations were evaluated: baseline (without any flow control), axial slots, axial slots
Gautham A. Amin   +2 more
doaj   +1 more source

Improvement of Moderately Loaded Transonic Axial Compressor Performance Using Low Porosity Bend Skewed Casing Treatment

open access: yesInternational Journal of Rotating Machinery, 2014
This paper presents experimental results of a single stage transonic axial flow compressor coupled with low porosity bend skewed casing treatment. The casing treatment has a plenum chamber above the bend slots.
Dilipkumar Bhanudasji Alone   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy