Results 111 to 120 of about 12,393,977 (220)

Progress Toward a Portable Artificial Lung: A Systematic Review

open access: yesArtificial Organs, Volume 50, Issue 11, Page 1520-1531, November 2026.
Eight portable respiratory assist devices were identified. The CE‐marked MobyBox and the FDA‐approved Breethe OXY‐1 system are in clinical use. Each device is substantially minimized to allow ambulation, but further work is required to address challenges related to anticoagulant management and safe mobilization. Created in BioRender. Svendsen, A. (2026)
Maja Munk Svendsen   +5 more
wiley   +1 more source

The effects of needleless connectors on catheter-related bloodstream infections

open access: yes, 2011
Needleless connectors, including the standard split septum and the luer-activated mechanical valve connectors, have been introduced into clinical practice to eliminate the risk of needlestick injuries by avoiding the use of needles when accessing the ...
Khalidi, Nabil   +7 more
core   +1 more source

Antibiotic Exposure and Risk of Acute Kidney Injury in Individuals With Staphylococcus aureus Bacteremia

open access: yesAPMIS, Volume 134, Issue 11, November 2026.
ABSTRACT Staphylococcus aureus bacteremia (SAB) is associated with acute kidney injury (AKI). Recent reports have suggested that isoxazolyl penicillins are associated with AKI. To further investigate the relationship between antibiotic treatment and risk of AKI in patients with SAB, we studied a cohort of adults with methicillin‐susceptible SAB.
Malene Vang   +6 more
wiley   +1 more source

Meta-analyses of skin antiseptics for the prevention of vascular catheter-related infection.

open access: yes, 2012
(A) Aqueous CHG versus aqueous PVI, outcome catheter colonisation. (B) Aqueous CHG versus aqueous PVI, outcome catheter-related bloodstream infection. (C) CHG plus alcohol versus aqueous PVI, outcome catheter colonisation.
Matthias Maiwald (137441)   +1 more
core   +1 more source

Pronounced Reductions in Plasma Citrulline Indicate Severe Intestinal Mucosal Barrier Injury During Induction Therapy for Pediatric Acute Myeloid Leukemia

open access: yesEuropean Journal of Haematology, Volume 117, Issue 5, Page 1275-1284, November 2026.
ABSTRACT Objectives Pediatric acute myeloid leukemia (AML) chemotherapy regimens are frequently burdened by fever episodes, systemic inflammation and bloodstream infections (BSI). Mucosal barrier injury may contribute to these complications, but its role in childhood AML remains uninvestigated.
Carla Warley Kjær   +8 more
wiley   +1 more source

Nursing‐Led Knowledge Translation Strategies to Improve Patient Safety in Hospital Settings: A Scoping Review

open access: yesJournal of Advanced Nursing, Volume 82, Issue 11, Page 9595-9608, November 2026.
ABSTRACT Aim To conduct a scoping review of nurse‐led Knowledge Translation strategies aimed at promoting and enhancing patient safety in hospital settings. Design Scoping review. Methods This review followed the Joanna Briggs Institute methodology and was reported according to PRISMA‐ScR.
Jhenyfer Amanda Ciriaco Canhete   +5 more
wiley   +1 more source

A case of catheter-related bloodstream infection caused by Mycobacterium phocaicum

open access: yes, 2013
We present a patient with double hit Burkitt's like lymphoma who developed a catheter-related bloodstream infection due to Mycobacterium phocaicum that was identified by rpoB gene sequencing.
Simkins, Jacques, Rosenblatt, Joseph D
core   +1 more source

Variability in Vascular Access Device Use, Dwell Time and Failure: Insights From Routine Nursing Documentation in a Multicentre Cohort Study

open access: yesJournal of Clinical Nursing, Volume 35, Issue 11, Page 4828-4838, November 2026.
ABSTRACT Aims To describe and compare institutional patterns of vascular access device use, dwell time, and failure, and to explore their implications for nursing practice. Design Retrospective multicentre observational cohort study. Methods Routinely collected nursing records of vascular access device insertion and removal were analysed from seven ...
Ismael Fernández‐Fernández   +8 more
wiley   +1 more source

Use of maximal sterile barrier precautions and/or antimicrobial-coated catheters to reduce the risk of central venous catheter-related bloodstream infection

open access: yes, 2008
Central venous catheter-related bloodstream infection is clinically important because of its high mortality rate. This prospective study shows by multivariate analysis that the use of maximal sterile barrier precautions (odds ratio, 5.205 [95% confidence
정구영   +3 more
core   +1 more source

Between Skin and Brain: A Systematic Review of 712 Cases 1976–2025 Reveals a Highly Diverse Disease Spectrum in Chaetothyriales

open access: yesMycoses, Volume 69, Issue 11, November 2026.
ABSTRACT Background Black yeast‐like species of the order Chaetothyriales cause superficial to life‐threatening systemic infections. Comprehensive global epidemiology data remain limited. Objectives This study aimed to analyze the global epidemiology, spectrum of pathogens, clinical manifestations and outcomes of Chaetothyriales infections.
Jiayi Li   +6 more
wiley   +1 more source