Results 131 to 140 of about 108,752 (267)
Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin +3 more
wiley +1 more source
Fractura intravascular de un catéter arterial: una complicación poco común pero real [PDF]
Ana Bernardino +3 more
doaj +1 more source
Optimization of Magnetic Milli‐Spinner for Robotic Endovascular Intervention
This work presents the design optimization of a multifunctional magnetic milli‐spinner for high‐speed propulsion and efficient clot debulking. The optimized design achieves an ultrafast swimming velocity of 55 cm/s (≈175 body lengths/s) in saline water, enabling stable upstream swimming against strong physiological flows and establishing magnetic milli‐
Lu Lu +3 more
wiley +1 more source
Hemodialysis central venous catheter scrub-the-hub protocol [PDF]
This protocol outlines a suggested approach to preparing catheter hubs prior to accessing the catheter for hemodialysis. It is based on evidence where available and incorporates theoretical rationale when published evidence is ...
core
Nitrosyl heme emerges as an extracellular nitrodilator that dilates arteries without crossing the cell membrane. Instead, heme‐NO mobilizes NO moieties from a preformed intracellular NO store within vascular smooth muscle, providing both functional and chemical evidence for the NANOS model, revealing a previously unrecognized mechanism of arterial ...
Taiming Liu +9 more
wiley +1 more source
Changes in the exclusion criteria in a clinical trial about arterial catheters patency
Regarding a clinical trial designed to compare the functionality of arterial catheters kept with heparin vs saline solution, a slow rate of case recruiting was detected.
Núria Grané Mascarell +3 more
doaj
The difficulty and complexity of lead extraction procedures increase with the age of the lead to be extracted. The extraction of old (>20 years) leads is more time-consuming and requires advanced tools and a complex technique.
Jun Li +7 more
doaj +1 more source
Cesar A Restrepo Valencia,1 Carlos A Buitrago Villa,1 Jose A Chacon Cardona21Internal Medicine, Nephrology, 2Epidemiology, Caldas University, Manizales, ColombiaBackground: We compared the results of four different methods of hemodialysis catheter ...
Restrepo Valencia CA +2 more
core
Retained Catheter Tip Fragment in the Abdominal Wall During Abdominal Paracentesis
Large-volume paracentesis is a safe procedure, but it has limited complications. We demonstrated a rare complication, including a retained catheter tip fragment in the abdominal wall during abdominal large-volume paracentesis.
Furkan Kaya, Tevfik Solakoğlu
core +1 more source

