Results 101 to 110 of about 1,188,920 (287)

Resonant cavity method for broadband dielectric measurements [PDF]

open access: yes, 1987
The project investigates the Cavity Perturbation Method (CRM) and design of a coaxial resonator covering a wide frequency band from 2.5 to 11.5 GHz. Using the published analyses for coaxial cavities, original theoretical analysis of Cavity Perturbation ...
Muhammad-Ahmad, Makki El-Tayyid
core  

Anaesthetic Considerations in the Video-assisted Thoracoscopic Excision of Pulmonary Aspergilloma: A Case Report [PDF]

open access: yesJournal of Clinical and Diagnostic Research
Video-assisted Thoracoscopy (VATS) is often used for diverse chest and lung ailments, which requires one-lung ventilation utilising a double-lumen tube. It involves small incisions and real-time imaging, resulting in enhanced postoperative recovery.
Vipul Krishen Sharma, Chandi Priya Singh
doaj   +1 more source

Thermomechanical Fatigue and Creep–Fatigue Interaction of Inconel 718 Additively Manufactured by Laser Beam Powder Bed Fusion

open access: yesAdvanced Engineering Materials, EarlyView.
Thermomechanical fatigue tests of laser beam powder bed fusion (PBF‐LB) Inconel 718 show that the additively manufactured material reaches almost the lifetimes of conventionally‐rolled material under no‐dwell conditions. Introducing dwell times at the maximum temperature markedly reduces the lifetimes due to pronounced grain boundary sliding associated
Stefan Guth   +6 more
wiley   +1 more source

Feedback control of oscillations in combustion and cavity flows [PDF]

open access: yes, 2010
This thesis considers the control of combustion oscillations, motivated by the susceptibility of lean premixed combustion to such oscillations, and the long and expensive development and commissioning times that this is giving rise to.

core   +2 more sources

Stafne Bone Cavity

open access: yesJournal of the Belgian Society of Radiology, 2015
A 53-year-old male was referred to the department of maxillofacial surgery for the extraction of a destructed wisdom tooth. A preoperative orthopantomogram revealed a well delineated ovoid, radiolucent lesion at the left angle of the mandible. For further lesion characterization, a dental CT scan and MRI were performed.
Schaerlaken, D. A.   +5 more
openaire   +6 more sources

Air‐Pressure–Actuated Vibroacoustic Metamaterial With Tunable Bandgap: Design, Modeling, and Characterization

open access: yesAdvanced Engineering Materials, EarlyView.
This article presents the design, modeling, and characterization of air‐pressure–actuated programmable vibroacoustic metamaterials (PVAMM). The study focuses on leveraging air pressure to dynamically tune resonance frequencies for effective noise attenuation.
William Kaal   +2 more
wiley   +1 more source

Gigahertz circular polarization oscillations in spin-polarized vertical-cavity surface-emitting lasers [PDF]

open access: yes, 2010
We analyze ultrafast circular polarization oscillations in a commercial vertical-cavity surface-emitting laser after spin injection at room temperature. The circular polarization exhibits faster dynamics than the intensity and longer persistence than the
Hofmann, M. R.   +11 more
core   +1 more source

Electrochemical Behavior of Flame‐Sprayed Sc‐Doped AlCoCrFeMo High‐Entropy Alloy Coatings in 3.5% Sodium Chloride Solution

open access: yesAdvanced Engineering Materials, EarlyView.
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar   +7 more
wiley   +1 more source

Inverse Identification of Energy‐Dependent Laser Absorptivity in NiTi Laser Powder‐Bed Fusion via Calibrated Melt Pool Simulation

open access: yesAdvanced Engineering Materials, EarlyView.
A combined experimental–computational framework identifies energy‐dependent laser absorptivity for NiTi in laser powder‐bed fusion, applicable to conduction and transition modes. Single‐track experiments and thermofluid smoothed particle hydrodynamics simulations are coupled through inverse analysis of melt pool geometry.
Mohamadreza Afrasiabi   +3 more
wiley   +1 more source

High‐Resolution Corrosion Fingerprinting of Alloy Libraries via Microdroplet Spectroelectrochemistry

open access: yesAdvanced Engineering Materials, EarlyView.
Ionic‐liquid microdroplet spectroelectrochemistry enables stable, localized electrochemical measurements over extended timescales. By coupling impedance spectroscopy, wetting analysis, finite‐element simulations, and operando Raman spectroscopy, it disentangles geometrical and electrochemical effects, opening new opportunities for rapid corrosion ...
Ekaterina Kurchavova   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy