Results 181 to 190 of about 301,057 (248)

Ratiometric Mycotoxin Detection in Living Plants With Dual‐Emissive Nanosensors

open access: yesAdvanced Materials, EarlyView.
A minimally invasive microneedle patch integrates carbon dot‐embedded metal–organic frameworks as nanosensors to detect a key fungal toxin in living plants. The nanosensor produces a ratiometric fluorescence signal that enables early, non‐destructive diagnosis of fungal infection before visible symptoms, offering a new biomaterials‐based strategy for ...
Yuliang Li   +9 more
wiley   +1 more source

A Unified Polymer Hydrogel Electrolyte Integrating Robust Adhesion, Self‐Healing, and Oxygen Permeability in Flexible Neutral Zn‐Air Batteries

open access: yesAdvanced Materials, EarlyView.
Flexible neutral Zn‐air batteries achieving a remarkable 3000‐cycle lifespan and withstanding 1000 bending cycles are reported. This performance is realized by employing a 3D physically cross‐linked neutral hydrogel electrolyte that integrates high adhesion, self‐healing, O2 permeability, and CO2 tolerance to resolve critical stability challenges ...
Zhenyu Sun   +3 more
wiley   +1 more source

E. coli Extracellular Matrix: A Tunable Composite With Hierarchical Structure

open access: yesAdvanced Materials, EarlyView.
The complex composite‐like mechanical behavior of E. coli biofilm matrix is the result of a synergic contribution of the rigid curli and swelling pEtN‐cellulose, and emerges from specific ratio and assembly conditions. The interactions between the two fibers govern biofilm hydration and characteristic wrinkling patterns, providing crucial insights for ...
Macarena Siri   +7 more
wiley   +1 more source

Near‐Unity Chiral Lasing Enabled by Quasi‐Bound States in the Continuum

open access: yesAdvanced Materials, EarlyView.
Nanoimprinted chiral array that supports bound states in the continuum is doped with an efficient non‐chiral molecule (Rhodamine‐B) acting as gain medium to produce fully circularly polarized lasing emission. The chiral lasing wavelength can be tuned across the emission band of Rhodamine‐B by adjusting the coating thickness of the TiO2 high refractive ...
Jose Mendoza‐Carreño   +5 more
wiley   +1 more source

Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management

open access: yesAdvanced Materials, EarlyView.
A soft contact lens sensor enables continuous, noninvasive monitoring of nocturnal intraocular pressure (IOP) under closed‐eye sleep conditions. By integrating a highly compliant inductive–capacitive circuit onto a commercial lens, the device achieves record sensitivity and stable performance.
Yumin Dai   +19 more
wiley   +1 more source

Home - About - Disclaimer - Privacy