Results 91 to 100 of about 72,402 (289)
Experimental Study of Ultra Shallow Floor Beams (USFB) with Perforated Steel Sections [PDF]
: In modern building construction design, floor spans are becoming longer. Hence, steel framed structures have become more competitive when compared with traditional reinforced concrete framed buildings. In order to minimise the structural section of the
D'Mello, C. +2 more
core
Evaluating Energy Absorption Performance of Filled Lattice Structures
Maximum stress must be considered to robustly evaluate energy absorber designs. This approach was applied to compare all types of absorbers in a single Ashby diagram and determine the utility of filling lattice voids with a second material. High‐performance fillers can improve the performance of lattices that are limited by buckling or catastrophic ...
Christian Bonney +2 more
wiley +1 more source
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk +7 more
wiley +1 more source
Behaviour of cellular beams at elevated temperatures
Cellular beams are beams that present openings in the web. The insertion of this openings can cause a good architectural characteristic, but the main reason is to improve the mechanical performance, overcoming larger spans compared to the original solid beams, reducing its weight in addition to the passage of technical installations trough the openings.
Sandri, Mychel +2 more
openaire +1 more source
A carbon‐free, as‐sintered MgO–steel cermet anode, fabricated via cold isostatic pressing using MgO–C refractory recyclate, was evaluated under laboratory‐scale K‐cryolite electrolysis at 800°C. Operation at this reduced temperature, combined with the electrolyte's limited electrical conductivity, led to an increase in cell voltage.
Farhan Hossain +7 more
wiley +1 more source
Elastic lateral-torsional buckling of cellular beams
Cellular beams are I-shaped steel sections with advantages provided by their circular web openings. This type of beam can have greater spans, be more slender and higher than the solid beams, being more prone to failure by lateral-torsional buckling.
Silva, Luana Vidoti da, Mesquita, L.M.R.
openaire +2 more sources
Cermets (60 vol.% AISI 316L stainless steel, 40 vol.% recycled MgO), intended for use in aluminum electrolysis, were pre‐oxidized in three furnaces with different heating technologies and subjected to a cryolite corrosion test. The different atmospheres influenced the formation of oxide layers, which in turn affected corrosion resistance and ...
Patricia Kaiser +4 more
wiley +1 more source
Additive manufacturing provides precise control over the placement of continuous fibres within polymer matrices, enabling customised mechanical performance in composite components. This article explores processing strategies, mechanical testing, and modelling approaches for additive manufactured continuous fibre‐reinforced composites.
Cherian Thomas, Amir Hosein Sakhaei
wiley +1 more source
Fostering Innovation: Streamlining Magnetocaloric Materials Research by Digitalization
Magnetocaloric cooling (MCE) is an environmentally friendly refrigeration method with great potential. Optimizing MCE materials involves the preparation and screening of large quantities of samples, which in turn generates a large amount of data. A digitalization approach is presented that uses ontologies, knowledge graphs, and digital workflows to ...
Simon Bekemeier +17 more
wiley +1 more source
The global shear capacity of steel–concrete composite downstand cellular beams with precast hollow-core units is an important calculation as it affects the span-to-depth ratios and the amount of material used, hence affecting the embodied CO2 calculation
Felipe Piana Vendramell Ferreira +6 more
doaj +1 more source

