Results 41 to 50 of about 479,248 (279)

Lavage prior to vertebral augmentation reduces the risk for cement leakage [PDF]

open access: yes, 2016
PURPOSE This study aimed at assessing the cement leakage rate and the filling pattern in patients treated with vertebroplasty, kyphoplasty and stentoplasty with and without a newly developed lavage technique.
Keel, Marius Johann Baptist   +11 more
core   +2 more sources

Arterial embolism due to massive cement leakage during total hip arthroplasty revision [PDF]

open access: yes, 2021
Total hip arthroplasty with cementing techniques leads to good clinical outcomes, but critical vascular complications can sometimes occur due to cement leakage into the pelvis.
Makida, Kazuya   +4 more
core   +1 more source

Application of Mechanical Nitrogen Filling Foam Cementing Technique in Shale Gas Wells

open access: yesShiyou jixie, 2022
Shale gas wells under complex conditions are faced with some cementing problems such as lost of circulation, low displacement efficiency and poor sealing effect.
Kuang Lixin   +6 more
doaj  

Lack of correlation between tubular dentine cement penetration, adhesiveness and leakage in roots filled with gutta percha and an endodontic cement based on epoxy amine resin

open access: yesJournal of Applied Oral Science, 2014
Objective: To analyze possible correlations among tubular dentine cement penetration, adhesiveness and apical leakage in fillings performed with gutta percha and an endodontic cement based on epoxy amine resin.
Ricardo MACHADO   +5 more
doaj   +1 more source

Cardiopulmonary Cement Embolism Following Cement-Augmented Pedicle Screw Fixation: A Narrative Review

open access: yesMedicina, 2023
Fixation using cement-augmented pedicle screws (CAPS) is being increasingly performed. However, CAPS-associated cement leakage is a critical problem that can lead to cardiopulmonary cement embolism (CPCE).
Tadatsugu Morimoto   +6 more
doaj   +1 more source

Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty

open access: yesJournal of Orthopaedic Surgery and Research, 2019
Background The risk factors, incidence, and clinical management of pulmonary cement embolism and neurological deficit during percutaneous vertebroplasty (PVP) were evaluated.
Ming-Kai Hsieh   +7 more
doaj   +1 more source

Transdiscal Cement Leakage During Vertebroplasty

open access: yesTzu Chi Medical Journal, 2009
AbstractBone cement leakage is a major cause of surgical complications during percutaneous vertebroplasty. A 78-year-old woman experienced transdiscal cement leakage during vertebroplasty for painful compression fractures of thoracic vertebrae 9 and 10 (T9 and T10).
Hsu, Wen-Chin, Lee, Ting-Chen
openaire   +1 more source

Cement leakage causes potential thermal injury in vertebroplasty [PDF]

open access: yesBMC Musculoskeletal Disorders, 2011
AbstractBackgroundPercutaneous vertebroplasty by injecting PMMA bone cement into the fractured vertebrae has been widely accepted in treatment of spinal compression fracture. However, the exothermic polymerization of bone cement may cause osseous or neural tissue injury.
Chen Lih-Huei   +3 more
openaire   +3 more sources

A Medium Viscous Acrylic Cement Enhances Uniformity of Cement Filling and Reduces Leakage in Cancellous Bone Augmentation [PDF]

open access: yes, 2011
Vertebroplasty is an efficient procedure to treat osteoporotic vertebral fractures. Cement leakage is considered to be the most severe complication during vertebroplasty. At high cement viscosities, the risk of leakage is reduced.
Andreas Boger, Kurtis Wheeler
core   +1 more source

3D Printed Photon Shield Assembly for Low‐Noise Visual Stimulation During Two‐Photon Imaging in Mice

open access: yesAdvanced Materials Technologies, EarlyView.
We present the Photon Shield, an open‐hardware system for low‐noise two‐photon calcium imaging during visual stimulation in mice. Combining a 3D‐printed headplate and rail‐mounted shield substantially reduces stray‐light contamination, as quantitatively verified. Functional validation confirms reliable cortical responses. Open design files enable broad
Gergely Katona   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy