Results 71 to 80 of about 408,870 (338)

Adaptive 4D‐Printed Vascular Stents With Low‐Temperature‐Activated and Intelligent Deployment

open access: yesAdvanced Functional Materials, EarlyView.
Microarchitected coronary artery stents were fabricated using a polycaprolactone (PCL)‐based shape memory polymer (SMP) composite via projection micro‐stereolithography (PµSL) 4D printing. By incorporating diethyl phthalate (DEP) as a plasticizer, the thermal transition temperature (Ttran) was modulated to about 37°C, enabling rapid and autonomous ...
Yannan Li   +12 more
wiley   +1 more source

Effect of Checklist Application on Performance of Intensive Care Nurses in Measuring Central Venous Pressure

open access: yesحیات, 2015
Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards.
Farshid Mirzaeipour   +4 more
doaj   +2 more sources

Norepinephrine Infusion and the Central Venous Waveform in a Porcine Model of Endotoxemic Hypotension with Resuscitation: A Large Animal Study

open access: yesJournal of Investigative Surgery
Background Venous waveform analysis is an emerging technique to estimate intravascular fluid status by fast Fourier transform deconvolution. Fluid status has been shown proportional to f0, the amplitude of the fundamental frequency of the waveform’s ...
Zachary R. Bergman   +7 more
doaj   +1 more source

RNA‐Micelles as Self‐Assembling Structures for Efficient Co‐Delivery of Synergistic siRNA and Nucleoside Analogues to Treat CRC Lung Metastasis

open access: yesAdvanced Functional Materials, EarlyView.
Two kinds of self‐assembled RNA micelles were used to co‐deliver synergistic siRNA and nucleoside analogues for the treatment of colorectal cancer lung metastases. Near‐complete elimination of lung cancer metastases was confirmed in an orthotopic lung metastasis model constructed using human colorectal cancer lung metastases patient surgical samples to
Kai Jin   +4 more
wiley   +1 more source

Central Venous Pressure Guided Fluid Management During Anaesthesia of a Phaeochromocytoma Patient with End Stage Renal Disease

open access: yesArchives of Anesthesia and Critical Care, 2017
A 42-year-old male with a 2-year history on dialysis for renal failure was admitted for adrenalectomy. We applied central venous catheter for this phaeochromocytoma case before the induction of anaesthesia.
Mohammadreza Kamranmanesh   +3 more
doaj  

From In‐Silico Optimized Microfabrication to Experimental Validation: Engineering a Tridimensional Epi‐Intraneural Interface

open access: yesAdvanced Functional Materials, EarlyView.
An epi‐intraneural interface is developed through in silico optimization and a novel tridimensional microfabrication pipeline. The device integrates penetrating and epineural contacts on a flexible substrate. Mechanical, electrochemical, and in vivo testing in rat and pig reveal robust implantation, low‐threshold activation, and site‐dependent ...
Federico Ciotti   +14 more
wiley   +1 more source

An Ultrafast Self‐Gelling Versatile Hydrogel for Rapid Infected Burn Wound Repair in Military Medicine

open access: yesAdvanced Functional Materials, EarlyView.
A self‐gelling PG@PAC (POD/Gel‐CDH@PA/CHX) powder is developed for infected burn care in austere settings. Upon contact with wound exudate, it instantly forms an adhesive hydrogel, providing simultaneous hemostasis, broad‐spectrum antibacterial activity, reactive oxygen species scavenging, and immunomodulation. In a murine model of S.
Liping Zhang   +14 more
wiley   +1 more source

Central Venous Pressure Monitoring; Introduction of a New Device

open access: yesArchives of Academic Emergency Medicine, 2018
Hemodynamic monitoring is needed in up to 58% of patients presented to the emergency department. Central venous pressure (CVP) monitoring is generally useful to assess general volume status.
Mahmood Ghafoori Yazdi   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy