Results 151 to 160 of about 6,692,759 (201)
Some of the next articles are maybe not open access.
Test Centrifuge Arrangement Analysis
2019Comparative analysis of configurations of test centrifuges designed for mechanical testing of devices and instruments has been performed. Schemes of centrifuges, rotor-balancing devices, have been considered. Recommendations for rotor aerodynamic casings design have been given.
Arkady N. Popov +2 more
openaire +1 more source
The testing and analysis of the centrifugal high-speed atomizer
2012 IEEE 11th International Conference on Cognitive Informatics and Cognitive Computing, 2012The centrifugal high-speed atomizer is running at high speed, it makes micron liquid-drop in order that chemical reaction happened between micron drop and harmful gas. Its function has direct impact to the emission produced from WTE plant. Meanwhile, the emission from the plant must meet the standard.
Youqing Ding, Guichuan Hu
openaire +1 more source
The Determination of Meningococcic Antibodies by a Centrifuge-Agglutination Test
The Journal of Immunology, 1945Summary and Conclusions A method for the determination of agglutinins against N. intracellularis by the use of the centrifuge is described and the theoretical reasons for its superiority are given. Four hundred and four specimens of serum from 121 subjects with and without meningococcal infections were examined by this method.
R L, MAYER, H F, DOWLING
openaire +2 more sources
Centrifuge model testing at Caltech
International Journal of Soil Dynamics and Earthquake Engineering, 1983Abstract In the past eight years a variety of model tests has been performed on the geotechnical centrifuge at Caltech. They include soil mechanics experiments, such as static and dynamic pile and foundation tests, and other investigations of a more geographical nature where ground faulting and earthquake motions have been modeled.
openaire +1 more source
A New Centrifugal Testing Method: Descending Gravity Test
Geotechnical Testing Journal, 2006Abstract This paper presents a new centrifugal testing method that has been developed to observe the effects of void ratio and overconsolidation ratio on the generation of undrained shear strength in cohesive soils. This new method provides soil profiles of constant overconsolidation ratio and varying void ratio throughout the sample ...
O Cinicioglu, D Znidarčić, H-Y Ko
openaire +1 more source
Soil Liquefaction Tests in the ISMGEO Geotechnical Centrifuge
2018Operational since 1988, the ISMGEO geotechnical centrifuge is a 240 g-ton centrifuge with a nominal radius of 2.2 m. The centrifuge can spin up a model of 400 kg up to 600 g. Since 2010 the centrifuge is equipped with a 1D shaking table able to reproduce real earthquake signals under an acceleration field up to 100 g.
Sergio Airoldi +2 more
openaire +2 more sources
Use of a Centrifugal Analyzer in Coagulation Testing
Seminars in Thrombosis and Hemostasis, 1983L P, Hills +3 more
openaire +2 more sources
[The gel centrifugation test in serologic compatibility testing].
Beitrage zur Infusionstherapie = Contributions to infusion therapy, 1991The gel centrifugation test is described in compatibility testing. The conventional method was modified resulting in easy handling for technical assistant. 2560 of compatibility testings were performed. 5% of more relevant antibodies could be detected compared with conventional tube test.
W, Hitzler +3 more
openaire +1 more source
Study on PIGA Test Method on Centrifuge
2007 International Conference on Computational Intelligence and Security (CIS 2007), 2007Yong-hui Qiao, Yu Liu, Bao-ku Su
openaire +2 more sources
Centrifuge modelling of landslides and landslide hazard mitigation: A review
Geoscience Frontiers, 2023Changdong Li, Huiming Tang, Kun Fang
exaly