Results 101 to 110 of about 950 (215)
Performance of bolted steel-beam to CFST-column joints using stiffened angles in column-removal scenario [PDF]
This paper presents three experimental investigations on the performance of steel-beam to CFST-column joints using stiffened angle, long bolts and fin plate under a middle column removal scenario. Three specimens were designed and tested.
Fu, F., Gao, S., Guo, L., Xu, M.
core +1 more source
Finite element analysis of steel beam-CFST column joints with blind bolts
The combined utilisation of concrete-filled steel tubular (CFST) columns and steel beams has increased in composite building construction in recent years.
Mirza, Olivia (R13978) +4 more
core
Ultimate compressive strength of 663 axially loaded CFST circular column samples
This circular column sample of CFST (Concrete-Filled Steel Tube) was obtained from reliable and well-regarded research sources. The dataset comprises 663 samples, each with 6 features: D_cm, t_cm, L_cm, fy_kN/cm2, fc_kN/cm2, and ...
Nguyen, Tran-Trung
core +1 more source
Behaviour of foamed concrete filled steel tubes (CFST) [PDF]
A concrete-filled steel tube (CFST) column consists of a steel tube filled with concrete. Original reason why this CFST concept was developed was to prevent shear failure and to improve ductility of short columns.
Mohd. Saman, Hamidah +4 more
core
Concrete-filled Hollow Rectangular Section Columns (RHS-CFST) are widely used in steel structures in seismic zones due to their ductility, energy dissipation, and load-bearing capacity.
DIF Fodil +3 more
doaj +1 more source
Behaviour of composite joints with concrete encased CFST columns under cyclic loading : experiments
Concrete-encased concrete filled steel tube (CFST) columns have been applied in some real structures in recent years, where they were connected with reinforced concrete (RC) beams or steel beams in a building. Seven composite joint models, including four
Han, Lin-Hai +2 more
core +1 more source
Due to their excellent mechanical features, concrete-filled steel tube (CFST) columns are usually employed in high-rise constructions; it is also significant to consider fire safety while designing buildings.
Christo George +6 more
doaj +1 more source
Seismic performance of concrete-encased CFST piers : experimental study
Concrete-encased concrete-filled steel tube (CFST) box members have been recently used as piers and arches in bridges owing to their high stiffness and strength.
Han, Lin-Hai +3 more
core +1 more source
The use of Convectional Concrete Column is often limited in high-rise Buildings due to the constraint from the architects on increasing size of the columns, so the composite columns provide appropriate solution to satisfy the architect and the Client ...
Abdelhamid Azzazy, Yasser
core
Incidents such as fires, explosions, and impacts may cause progressive collapse of building. Since the 20th century, as terrorist activities in the world have been increasing year by year, experts and scholars around the world have begun to pay attention
Wenda WANG, Long ZHENG, Guoqiang WEI
doaj