Results 31 to 40 of about 18,264 (256)

Circuit design of VLSI for microelectronic coordinate-sensitive detector for material element analysis [PDF]

open access: yesTekhnologiya i Konstruirovanie v Elektronnoi Apparature, 2012
There has been designed, manufactured and tested a VLSI providing as a part of the microelectronic coordinate-sensitive detector the simultaneous elemental analysis of all the principles of the substance.
Sidorenko V. P.   +2 more
doaj   +2 more sources

Translating whole‐genome doubling into precision medicine in cancer

open access: yesMolecular Oncology, EarlyView.
Whole‐genome doubling creates a WGD‐positive tumor state characterized by persistent chromosomal instability, karyotypic diversification, and cellular stress. These same biological pressures drive aggressive tumor evolution while exposing therapeutic vulnerabilities, providing a rationale for WGD‐informed precision medicine. Whole‐genome doubling (WGD)
Sejung Lee, Junghyeok Lim, Jinhyuk Bhin
wiley   +1 more source

Polarization‐resolved femtosecond Vis/IR spectroscopy tailored for resolving weak signals in biological samples using minimal sample volume

open access: yesFEBS Open Bio, EarlyView.
Unique biological samples, such as site‐specific mutant proteins, are available only in limited quantities. Here, we present a polarization‐resolved transient infrared spectroscopy setup with referencing to improve signal‐to‐noise tailored towards tracing small signals. We provide an overview of characterizing the excitation conditions for polarization‐
Clark Zahn, Karsten Heyne
wiley   +1 more source

An 8.72 µW Low-Noise and Wide Bandwidth FEE Design for High-Throughput Pixel-Strip (PS) Sensors

open access: yesSensors, 2021
The front-end electronics (FEE) of the Compact Muon Solenoid (CMS) is needed very low power consumption and higher readout bandwidth to match the low power requirement of its Short Strip application-specific integrated circuits (ASIC) (SSA) and to handle
Folla Kamdem Jérôme   +6 more
doaj   +1 more source

UiO‐66 metal–organic frameworks in biomedicine: From structural tunability to bioimaging, photodiagnostics, and photodynamic cancer therapy

open access: yesFEBS Open Bio, EarlyView.
UiO‐66(Zr) metal–organic frameworks are chemically stable, biocompatible, and highly tunable nanomaterials. Their modular structure enables controlled drug delivery, multimodal bioimaging, and light‐activated photodynamic therapy, supporting integrated diagnostic and therapeutic (theranostic) applications in cancer and biomedical research.
Veronika Huntošová   +2 more
wiley   +1 more source

Design of a charge sensitive spectroscopy amplifier for Compton camera

open access: yesJournal of Physics: Conference Series, 2017
A charge sensitive spectroscopy amplifier has been designed to couple with the silicon strip detector of a Compton camera. The amplifier was optimized by using a wave form generator and the output gain of 1012V/C was achieved when the shaping time is 1μs.
Wei Wang   +4 more
openaire   +1 more source

Malformin A1–mediated cytotoxicity in ovarian cancer cells occurs through pyroptosis and autophagy

open access: yesFEBS Open Bio, EarlyView.
This study investigated the effects of the natural compound Malformin A1 (MA1) on the cytoskeleton that regulates cell proliferation and migration. Disruption of the cytoskeleton can impair these processes and promote cancer cell death. MA1 disrupted cytoskeletal organization, induced DNA damage, inflammation, activated autophagy, and pyroptosis ...
Nada Abdullah Hassan   +11 more
wiley   +1 more source

Simulation study on time resolution optimization of silicon drift detector

open access: yesHe jishu, 2021
BackgroundThe silicon drift detector (SDD) has been widely used in space exploration in recent years. The SDD has outstanding energy resolution, but its time resolution is not very satisfactory.
YU Nian   +5 more
doaj   +1 more source

Charge-Sensitive Poly-Silicon TFT Amplifiers for a-Si:H Pixel Particle Detectors [PDF]

open access: yesMRS Proceedings, 1992
ABSTRACTPrototype charge-sensitive poly-Si TFT amplifiers have been made for the amplification of signals (from an a-Si:H pixel diode used as an ionizing particle detector). They consist of a charge-sensitive gain stage, a voltage gain stage and a source follower output stage. The gain-bandwidth product of the amplifier is ∼ 300 MHz. When the amplifier
Cho, G.   +3 more
openaire   +2 more sources

Purification and preparation of Marchantia polymorpha Auxin Response Factor 2 for phase separation studies

open access: yesFEBS Open Bio, EarlyView.
We describe detailed protocols for the purification and preparation of Marchantia polymorpha Auxin Response Factor 2 (MpARF2). This protein is fused to an MBP solubility tag and an mNG fluorescent tag and is purified from Escherichia coli. The presented procedures make it possible to study MpARF2 assemblies, which could arise from phase separation ...
Bas Janssen   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy