Results 81 to 90 of about 18,264 (256)

Radiation-hardened-by-design preamplifier with binary weighted current source for radiation detector

open access: yesNuclear Engineering and Technology
This paper presents a radiation-hardened-by-design preamplifier that utilizes a self-compensation technique with a charge-sensitive amplifier (CSA) and replica for total ionizing dose (TID) effects.
Minuk Seung   +3 more
doaj   +1 more source

Low Noise Charge Sensitive Amplifier with Low Input Impedance [PDF]

open access: yesIEEE Transactions on Nuclear Science, 1981
This amplifier was designed for use in a large array of proportional wire chambers with charge division readout and for cathode readout of proportional chambers. The single stage high gain (104) amplifier with FET input has low component count, low cost, and a high packing density of 32 channels per double-sided P. C. board.
openaire   +1 more source

Two Coexisting Pathways to Volatility in Valence‐Change Memory Devices

open access: yesAdvanced Functional Materials, EarlyView.
Volatile VCM‐type memristive devices exhibit current relaxation after resistive switching, but their microscopic origin remains debated. Using pulsed measurements and a new Tunnel‐DLTS approach on Pt/SrTiO3/Nb:SrTiO3 devices, we show that post‐SET volatility is predominantly ionic, while electronic contributions—arising from quasi‐Fermi‐level ...
Johannes Hellwig   +3 more
wiley   +1 more source

Unusual Temperature‐Enhanced Bulk Photovoltaic Effect Beyond the Centrosymmetric Phase in CuCrP2S6 van der Waals Crystals

open access: yesAdvanced Functional Materials, EarlyView.
Contrary to conventional expectations, the bulk photovoltaic effect in CuCrP2S6 is enhanced rather than suppressed upon transitioning into the crystallographically centrosymmetric phase. Dynamic Cu‐ion disorder creates transient polar states, which substantially amplifies zero‐bias photocurrent (shift‐current) generation, establishing dynamic symmetry ...
Ryoga Murata, Takao Sasagawa
wiley   +1 more source

One‐Step Curcumin‐Mediated Multiphoton Lithography for Bioactive 3D Scaffolds

open access: yesAdvanced Functional Materials, EarlyView.
Curcumin‐mediated multiphoton lithography enables one‐step fabrication of highly architected complex gelatin methacryloyl scaffolds by exploiting curcumin as a multifunctional bioactive photoinitiator. The resulting 3D structures support mesenchymal stem cell adhesion, proliferation, and migration, while exhibiting dual antibacterial activity through ...
Myrto Charitaki   +7 more
wiley   +1 more source

Tailored Diketopyrrolopyrrole Derivatives for Efficient Deep‐Red Organic Lasers

open access: yesAdvanced Functional Materials, EarlyView.
Tailored diketopyrrolopyrrole derivatives exhibit high stable amplified spontaneous emission with single or dual bands. Incorporated into distributed‐feedback lasers based on one‐ and two‐dimensional dichromated‐gelatin diffractive gratings, these materials provide a robust, flexible platform for integrated organic deep‐red light sources. ABSTRACT Deep‐
Pablo Pasqués‐Gramage   +10 more
wiley   +1 more source

Design of Low-power Consumption Front-end CMOS Chip Circuit for Boron Nitride Personal Dosimeter

open access: yesYuanzineng kexue jishu
In the context of radiation monitoring for occupational safety, personal dosimeters require highly sensitive and energy-efficient electronic interfaces.
LIU Zhan, LIU Haifeng, HE Gaokui, HUANG Xinyi, SUN Jiayu
doaj   +1 more source

An Edible Chitosan‐Based Acoustic Sensor for Sound‐Responsive Actuation in Edible Robots

open access: yesAdvanced Functional Materials, EarlyView.
This study introduces an edible acoustic sensor for robotic food and edible robotics. Built from a chitosan piezoelectric film between gold electrodes, the sensor enables acoustic communication through ON/OFF keying. Integrated into an edible robot with pneumatically actuated arms and neck, it responds to high‐frequency tones.
Valerio Francesco Annese   +8 more
wiley   +1 more source

Digital signal processing application in nuclear spectroscopy [PDF]

open access: yesЯдерна фізика та енергетика, 2009
Digital signal processing algorithms for nuclear particle spectroscopy are described along with a digital pile-up elimination method applicable to equidistantly sampled detector signals pre-processed by a charge-sensitive preamplifier.
O. V. Zeynalova   +3 more
doaj  

Wearable Kirigami‐Apertured Capacitive Sensors for Continuous Cardiac Volumetric Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A wearable kirigami‐apertured carbon nanotube‐paper composite (K‐CPC) capacitive sensor enables cardiac volumetric monitoring. The kirigami process creates a central aperture with cantilevered fibers that confine the electric field, enhancing both sensitivity and lateral resolution.
Yu‐Jen Cheng   +4 more
wiley   +1 more source