Results 31 to 40 of about 2,195,854 (291)
In recent years, interest in screen-printed electrodes (SPEs) has grown due to their wide range of applications. Diclofenac (DCF), a widely used non-steroidal anti-inflammatory drug, is a subject of interest in pharmaceutical research as well as ...
Ana-Raluca Măghinici +2 more
doaj +1 more source
An Electrochemical-DNA biosensor (E-DNA biosensor) was prepared successfully for electrochemical detection of a target DNA sequence, and the effective surface of the electrode was designed in order to achieve high sensitivity.
Hyo-Eun Lee, Yun Ok Kang, Seong-Ho Choi
doaj +1 more source
Glassy carbon electrode modified with hybrid films containing inorganic molybdate anions trapped in organic matrices of chitosan and ionic liquid for the amperometric sensing of phosphate at neutral pH [PDF]
This work reports an amperometric method for phosphate analysis based on the use of a surface modified glassy carbon electrode (GC). In one configuration of the electrode the surface is modified with ammonium heptamolybdate incorporated in chitosan ...
Singh, P. +5 more
core
ABSTRACT Objective Variants in SLC6A1, encoding the GABA transporter 1 (GAT‐1), cause epilepsy, autism spectrum disorder, and developmental delay via loss of GABA uptake, impaired trafficking, and ER retention. We previously found that 4‐Phenylbutyrate (PBA), an FDA‐approved drug, restores GABA uptake and reduces seizures in SLC6A1‐related disorders ...
Melissa B. DeLeeuw +5 more
wiley +1 more source
Poly (acridine red) modified glassy carbon electrode was used for the detection of dopamine in the presence of ascorbic acid in a pH 7.4 phosphate buffer solutions (PBS) by cyclic voltammetry and differential pulse voltammetry.
Zhousheng Yang +3 more
doaj +1 more source
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar +7 more
wiley +1 more source
An Electrochemical Enzymatic Biosensor Based on Au/FGs/sol-gel-GOx Composite/Nafion
We have reported an electrochemical glucose biosensor based on the sol-gel derived composites with glucose oxidase (GOx) and nafion on chemically functionalized graphene sheets (FGs).
Mohammad Faruk Hossain +3 more
doaj +1 more source
This article investigates the dependence of the properties on the manufacturing orientation in the form of the inclination angle to the build plate of LPBF‐fabricated NiTi rods with a diameter of 150–220 µm. Metallographic, chemical, thermal, and mechanical characterization show behavior under identical manufacturing conditions that ranges from ...
Sandra Herzig +2 more
wiley +1 more source
The use of soybean peroxidase in amperometric biosensors [PDF]
Traditionally Horseradish peroxidase (HRP) the archetypal class III plant peroxidase has been investigated with respect to chemical modifications, organic solvent tolerance studies, reaction kinetics, kinetics in organic solvents, immunohistochemical and
Carolan, Neil
core +2 more sources
The 1.6-hexanedithiol (HDT) chemically modified gold (HDT/Au) electrode were prepared by self-assembly. The HDT modified layer blocked the heterogeneous electrolysis of [Fe (CN)6]3-/4- strongly except sites of pinholes and defects which behaved like ...
Lixin Cao +4 more
doaj +1 more source

