Results 241 to 250 of about 143,960 (307)

Size‐specific dose estimates calculated using patient size measurements from scanned projection radiograph in high‐resolution chest computed tomography

open access: yesJournal of Medical Radiation Sciences, Volume 72, Issue 1, Page 85-92, March 2025.
This study established that patient's lateral width measurements made from scanned projection radiograph (SPR) is an overestimate compared to those measured from tomographic slices by about 10%. Size‐specific dose estimates (SSDE) calculated using lateral width measured from SPR correlates well with SSDE calculated using water equivalent diameter of ...
Ajit Brindhaban
wiley   +1 more source

Chest Tube [PDF]

open access: bronze, 2013
Kyle T. Amber
openalex   +1 more source

Proposed Diagnostic Reference Levels for Frequently Performed Paediatric Radiographic Examinations

open access: yesJournal of Medical Radiation Sciences, EarlyView.
Paediatric diagnostic reference levels (DRLs) are weight‐stratified dose levels for typical medical imaging examinations for broadly defined types of equipment. The 75th percentiles of the FRLs across the nine X‐ray units from five centres in Australia were calculated as the proposed Local DRLs (LDRLs).
Edel Doyle   +4 more
wiley   +1 more source

Your C‐Arm May Be Dose Optimised but Is Your Surgical Procedure? The Evaluation and Dose Optimisation of Positioning Aids Used in Paediatric Image Guided Surgery

open access: yesJournal of Medical Radiation Sciences, EarlyView.
This study objectively evaluated the impact of positioning aids on radiation dose and image quality (IQ) in paediatric image guided surgery (IGS) and the potential for dose optimised imaging via the choice of positioning aid type selected for clinical use.
Dalia Dinham   +4 more
wiley   +1 more source

Motion-activated prevention of clogging and maintenance of patency of indwelling chest tubes [PDF]

open access: bronze, 2014
Jamshid H. Karimov   +7 more
openalex   +1 more source

Analysis of multichannel intraluminal impedance and pH monitoring values in children with cerebral palsy: A comparative multicenter study

open access: yesJournal of Pediatric Gastroenterology and Nutrition, EarlyView.
Abstract Objectives To compare the features of multichannel intraluminal impedance and pH monitoring (MII‐pH) tracings in children with cerebral palsy (CP) and children without CP. Methods Multicenter, retrospective, analytical study. We examined tracings of children aged 1 to 15 years old, evaluated from May 2017 to January 2024.
Cristina Lorenzo   +22 more
wiley   +1 more source

Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage [PDF]

open access: green, 2014
Albert H. Olivencia‐Yurvati   +8 more
openalex   +1 more source

Genital Crohn's disease in pediatrics and genetic associations

open access: yesJPGN Reports, EarlyView.
Abstract Genital edema is a rare presentation of Crohn's disease (CD), also known as metastatic CD (MCD). This may precede, co‐occur with, or follow gastrointestinal symptoms and present a diagnostic challenge. We aimed to characterize the features, clinical courses, pathogenesis, and outcomes of patients with MCD to increase understanding and promote ...
Erica Chang   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy