The paper proposes a diesel engine-based trigeneration system using a thermal storage for applications with simultaneous heating, cooling and power demand and where grid electricity is not available. A thermodynamic analysis is presented for the proposed
Mahesh Shelar, G.N. Kulkarni
doaj +1 more source
The results of calculation of two stage gas turbine unit intake air cooling processes with previous cooling by absorption lithium-bromide chiller and deep cooling by ejector chiller are presented.
Андрей Николаевич Радченко +3 more
doaj +1 more source
Dynamic Model for Small-Scale Ammonia-Water Absorption Chiller [PDF]
Optimization of the performance of absorption systems during transient operations such as start-up and shut-down to minimize lifetime costs is particularly important for small-capacity chillers and heat pumps.
Garimella, Srinivas +3 more
core +1 more source
Energy analysis of Chiller-Dry Cooler in air conditioning applications [PDF]
Sürdürülebilir enerji için yeni teknoloji ve ürünlerin etkin ve verimli kullanılması oldukça önemlidir. Hemkonut hem de endüstride geniş bir uygulama alanına sahip chiller-kuru soğutucu ikilisi de bu kapsamdadır.Dış hava sıcaklıklarına bağlı olarak kuru ...
İNAN, AHMET TALAT, Ahmet Talat İnan
core +3 more sources
Comparison of Environmental Performance of Cooling Sources of Air-Conditioning
According to life cycle assessment theory and standards of ISO, the model of life cycle inventory of energy of cooling sources was developed and a method of life cycle assessment was introduced. Common cooling sources (screw chiller, centrifugal chiller,
黄志甲, 张旭
doaj +2 more sources
Chiller Performance Analysis Of Multiple Faults
Chiller is one source of electricity consumption in buildings. For this reason, keeping the performance of the chiller always at optimum is necessary to limit excessive energy consumption. This paper aims to analyze the performance of the chiller against
Rusjdi, Halim +3 more
core +1 more source
A Reduced GWP Replacement for HFC-134a in Centrifugal Chillers: XP10 Measured Performance and Projected Climate Impact [PDF]
The performance of XP10, a new refrigerant with a reduced GWP, in a centrifugal chiller designed for HFC-134a with a cooling capacity of 1969.44 kW (560 tons) was measured under full and part load conditions and compared to performance with HFC-134a ...
Kulankara, Satheesh +2 more
core +1 more source
The chiller operating data has unbalanced,non-Gaussian,non-linear,noise-containing characteristics,which poses a challenge for data-based chiller fault diagnosis.Aiming at these characteristics,a chiller fault diagnosis method based on Minority ...
潘进 +4 more
doaj
Nitrogen chiller acceptance test procedure [PDF]
This document includes the inspection and testing requirements for the Nitrogen Chiller unit. The Chiller will support the Rotary Mode core Sampling System during the summer.
Kostelnik, A.J.
core +1 more source
Researchers investigated the characteristics and operation of chiller plants in inpatient buildings in southwestern China. The GN (Gordon-Ng) chiller model and ε- NTU cooling tower model to calculate the maximum cooling capacity of the chiller with wet ...
Yang Yuan +4 more
doaj +1 more source