Results 51 to 60 of about 16,838 (222)
This study presents a photodetector based on atomically thin MoS2 on an InP substrate, forming an n‐MoS2/p‐InP type‐II staggered heterojunction. The device exhibits excellent rectifying properties with an ideality factor of 1.57 and achieves a peak photoresponsivity of 960 mA W−1, while MoS2 provides stable passivation for InP. III–V semiconductors are
Dong Hwi Choi +8 more
wiley +1 more source
Surface pressure and temperature direct the assembly of P(NIPAM‐b‐AEMA) at the air‐water interface, transforming continuous films into tunable micellar nanodomains. The thermoresponsive P(NIPAM) block enables temperature‐controlled changes in domain size and order.
Miriam Peña‐Figueroa +3 more
wiley +1 more source
Innovative Turbine Intake Air Cooling Systems and Their Rational Designing
The efficiency of cooling ambient air at the inlet of gas turbines in temperate climatic conditions was analyzed and reserves for its enhancing through deep cooling were revealed. A method of logical analysis of the actual operation efficiency of turbine
Andrii Radchenko +4 more
doaj +1 more source
Pulsed electromagnetic fields induce second harmonic ultrasound generation in magnetic nanoparticles under isothermal conditions without heating. Non‐aligned and magnetically pre‐aligned nanoparticle clusters significantly enhance acoustic emission amplitude.
R. Marqués‐Gómez +6 more
wiley +1 more source
multi-chiller system scheduling with storage unit
The data is result of robust scheduling a multi-chiller system with a chilled-water storage ...
sadat mohammadi, M (via Mendeley Data) +2 more
core +3 more sources
Fault Diagnosis of Chillers Based on Association Classification Rules
Most of the existing data-driven fault diagnosis methods are based on the black box model. Although their accuracy is high, it is difficult to explain the diagnosis process and result.
Shi Daliang +3 more
doaj
Energetic analysis in a hot water system: A hotel facility case study
This paper evaluates the energy operational performance of a system to produce domestic hot water, from the use of waste heat in a centralized air conditioning system in a hotel in Cuba. The hotel facility has two different chillers capacities, where the
Yarelis Valdivia Nodal +6 more
doaj +1 more source
Breaking the ice: multiple origins of ice‐binding/antifreeze proteins
Ice‐binding proteins (IBPs) evolved independently in many organisms during Cenozoic cooling and glaciation. In flounders, α‐helical IBPs evolved from an antiviral protein, while similar IBPs arose independently from different progenitors in three other fish lineages.
Laurie A. Graham, Peter L. Davies
wiley +1 more source
G-89B, chiller utility, 22 April 1994
from Chiller Plant Site (G-89B)--Construction--Briefing Slides [see also 6:2 ...
core +1 more source
Chillers usually account for a major part of the overall energy consumption in commercial buildings. To improve the energy efficiency of chillers, we present an optimal chiller loading control strategy based on the best-performance line of the chiller ...
Ning Yupiao +4 more
doaj