Results 51 to 60 of about 6,302 (210)

Fault Diagnosis of Chillers Based on Association Classification Rules

open access: yesZhileng xuebao, 2020
Most of the existing data-driven fault diagnosis methods are based on the black box model. Although their accuracy is high, it is difficult to explain the diagnosis process and result.
Shi Daliang   +3 more
doaj  

Renewable Energy Integration Into the Injection Molding Quotation Process. Design and Technologies for Polymeric and Composites Products

open access: yesMacromolecular Symposia, EarlyView.
ABSTRACT Efficient energy management is a requirement for advanced factories, which require vast amounts of energy to operate and are often powered by a single grid connection with varying prices caused by fluctuations. These types of industrial consumers often choose to adopt local renewable energy generators.
L. M. Peța, C. G. Opran
wiley   +1 more source

Optimal Operation Strategy of Multiple Chiller System Based on the Best- Performance Line of History Data

open access: yesZhileng xuebao, 2020
Chillers usually account for a major part of the overall energy consumption in commercial buildings. To improve the energy efficiency of chillers, we present an optimal chiller loading control strategy based on the best-performance line of the chiller ...
Ning Yupiao   +4 more
doaj  

Analysis of potential energy and cost savings of replacing air-cooled chillers with water-cooled chillers: A case study in hotel building in tropical climate

open access: yesEngineering and Applied Science Research, 2023
Selecting the type of chillers to be used in commercial buildings is critical considering their high energy consumption, which consequently requires the use of chillers with higher efficiency in order to improve the energy efficiency of buildings and ...
Arka Dwinanda Soewono   +3 more
doaj  

Modeling and Optimizing a Chiller System Using a Machine Learning Algorithm

open access: yesEnergies, 2019
This study was conducted to develop an energy consumption model of a chiller in a heating, ventilation, and air conditioning system using a machine learning algorithm based on artificial neural networks.
Jee-Heon Kim   +2 more
doaj   +1 more source

Wet‐Transferred MoS2 on Passivated InP: A Van der Waals Heterostructure for Advanced Optoelectronic Applications

open access: yesphysica status solidi (RRL) – Rapid Research Letters, Volume 19, Issue 5, May 2025.
This study presents a photodetector based on atomically thin MoS2 on an InP substrate, forming an n‐MoS2/p‐InP type‐II staggered heterojunction. The device exhibits excellent rectifying properties with an ideality factor of 1.57 and achieves a peak photoresponsivity of 960 mA W−1, while MoS2 provides stable passivation for InP. III–V semiconductors are
Dong Hwi Choi   +8 more
wiley   +1 more source

Understanding Interactions Between Sustainable Development Goals Within and Between Policy Programmes: The Case of Kenya's Dairy Sector

open access: yesSustainable Development, EarlyView.
ABSTRACT Achieving Agenda 2030 depends on addressing interactions between the sustainable development goals (SDGs). In this paper, we conceptualize SDG interactions as synergies or trade‐offs, incoming or outgoing, and internal or external, and analyze how SDG 2 (Zero Hunger) interacts with other SDGs within and across policy programmes that support ...
Annita Jepchirchir Kirwa   +3 more
wiley   +1 more source

Hierarchically Biporous Wick Vapor Chamber With Micro/Nano Condenser for Exceeding 600 W/cm2 Heat Dissipation

open access: yesSmall, EarlyView.
An integrated vapor chamber couples a hierarchically biporous copper wick with a micro/nano‐textured superhydrophobic condenser to form a self‐sustained liquid–vapor loop. The device dissipates extreme heat fluxes above 600 W/cm2, even when the condenser is above the heater, by overcoming the permeability‐capillarity trade‐off in conventional vapor ...
Ya‐Nan Li   +4 more
wiley   +1 more source

Recommissioned Energy Control Strategy for RTE Television Centre's Chilled Water System

open access: yesJournal of Sustainable Design and Applied Research in Innovative Engineering of the Built Environment, 2012
This paper investigates the energy performance of a building’s chilled water system (CHWS), primarily focusing on the systems direct electrical energy consumption and the potential for delivering improvements to increase the overall operational ...
James McConnologue
doaj   +1 more source

Dry Development of Dry Coated Sn‐Based Inorganic Resist for Defect‐Suppressed and High‐Resolution Patterning Process

open access: yesSmall Methods, EarlyView.
This work compares conventional wet development and asynchronously pulsed plasma development for Sn‐based inorganic resists under delay and AMC exposure. While wet development induces CD variation, scumming, and bridging, pulsed plasma enables selective removal of non‐exposed regions, mitigating contamination effects and achieving defect‐suppressed ...
Hee Ju Kim   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy