Results 101 to 110 of about 336,529 (337)
The chemical composition and band alignment are systematically investigated at the TiO2/InP heterointerface. Thin TiO2 films are deposited by ALD on atomically ordered, P‐terminated p‐InP(100). By combining UPS, XPS, and ab initio molecular dynamics, the atomistic structure and electronic alignment are revealed.
Mohammad Amin Zare Pour +11 more
wiley +1 more source
This study investigates H4TBAPy‐based metal–organic frameworks (MOFs) ‐ NU‐1000, NU‐901, SrTBAPy, and BaTBAPy ‐ for multiphoton absorption (MPA) performance. It observes topology‐dependent variations in the 2PA cross‐section, with BaTBAPy exhibiting the highest activity.
Simon N. Deger +10 more
wiley +1 more source
Durability investigation of Calvaria Bridge and electrochemical realkalinisation as a preventive measure [PDF]
The purpose of this study is to investigate the performance of reinforced concrete structures during their service life. Environmental attacks, such as the atmospheric carbon dioxide and the deicing chloride salts ingression, may seriously affect both ...
Meda NEDELCU, Camelia NEGRUTIU
doaj
Predicting the steady state thickness of passive films in order to prevent degradations of implant [PDF]
Some implants have approximately a lifetime of 15 years. The femoral stem, for example, should be made of 316L/316LN stainless steel. Fretting corrosion, friction under small displacements, should occur during human gait, due to repeated loadings and un ...
Geringer, Jean +2 more
core +2 more sources
The SERS spectra of reporter molecules adsorbed on chiral gold nanorods depends on the handedness of circularly polarized light (CPL‐SERS). The bisignate plasmonic CD spectra of chiral nanorods provides wavelength‐dependent CPL‐SERS. Selective discrimination of chiral nanorod handedness and different Raman reporters allow highly sensitive codification ...
Andrés Serrano‐Freijeiro +9 more
wiley +1 more source
Benzalkonium chloride induces anterior chamber inflammation in previously untreated patients with ocular hypertension as measured by flare meter: a randomized clinical trial [PDF]
Anna M. Stevens +3 more
openalex +1 more source
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin +7 more
wiley +1 more source
Reducing concrete permeability by using natural pozzolans and reduced aggregate-to-pasteratio
Improved durability of concrete is mainly achieved with low-permeability. Permeability depends on permeability of the bulk cement paste (CP) and that of its interfacial transition zone (ITZ).
Fernando Bustos +3 more
doaj +1 more source

