Results 151 to 160 of about 1,832 (200)
Expansion Circuit Breaker as a D. C. High-Speed Circuit Breaker
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
2017
<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC ...
+7 more sources
<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC ...
+7 more sources
Test Circuits for HVDC Circuit Breakers
IEEE Transactions on Power Delivery, 2017High voltage direct current circuit breakers (HVDC CBs) are necessary for reliable and safe operation of future multi-terminal meshed HVDC grids. So far no commercially mature products of such equipment exist. A few industrial concepts as a result of advances in power electronics have been proposed and prototypes have been built.
N. A. Belda, R. P. P. Smeets
openaire +1 more source
Transactions of the American Institute of Electrical Engineers, 1942
DURING the past few years the rapid expansion of mercury-arc rectifier installations at 600 volts d-c, both as to the total kilowatts installed and the relatively large number of units operated in parallel, has emphasized the importance of switchgear in providing suitable rectifier operation.
D. I. Bohn, Otto Jensen
openaire +1 more source
DURING the past few years the rapid expansion of mercury-arc rectifier installations at 600 volts d-c, both as to the total kilowatts installed and the relatively large number of units operated in parallel, has emphasized the importance of switchgear in providing suitable rectifier operation.
D. I. Bohn, Otto Jensen
openaire +1 more source
Circuit Breaker Protection for Industrial Circuits
Transactions of the American Institute of Electrical Engineers, 1933The demand for continuity of service to customers, together with the need to reduce maintenance costs, and increase the safety to operators and property, has made it necessary to improve the protective devices used in the distribution circuit. In the past, this protection has been provided by knife switches and fuses.
H. J. Lingal, O. S. Jennings
openaire +1 more source
Electrical Engineering, 1943
Airplane circuit breakers are recognized as important units in the electrical systems of military aircraft. The design of such circuit breakers can be combined with switching and contactor functions. This makes possible the use of welldeveloped switch and contactor structures.
openaire +1 more source
Airplane circuit breakers are recognized as important units in the electrical systems of military aircraft. The design of such circuit breakers can be combined with switching and contactor functions. This makes possible the use of welldeveloped switch and contactor structures.
openaire +1 more source
2022
<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC
openaire +1 more source
<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC
openaire +1 more source
2020 IEEE Electric Power and Energy Conference (EPEC), 2020
Interruption of fault current with delayed current zeros (DCZ) is one of the peculiarities of generator circuit-breaker (GCB) that differentiates it from other medium-voltage and high-voltage circuit-breakers. This paper aims to provide a guideline for precise calculation of short-circuit current requirements for GCB.
Priyanka Gugale, Mirko Palazzo
openaire +1 more source
Interruption of fault current with delayed current zeros (DCZ) is one of the peculiarities of generator circuit-breaker (GCB) that differentiates it from other medium-voltage and high-voltage circuit-breakers. This paper aims to provide a guideline for precise calculation of short-circuit current requirements for GCB.
Priyanka Gugale, Mirko Palazzo
openaire +1 more source

