Results 221 to 230 of about 2,406,137 (252)
Some of the next articles are maybe not open access.
IEEE Transactions on Power Delivery
The rated current and short-circuit current of the large-capacity generator circuit breaker (GCB) far exceed the limit of a single vacuum circuit breaker (VCB).
Xiangyu Han +8 more
semanticscholar +1 more source
The rated current and short-circuit current of the large-capacity generator circuit breaker (GCB) far exceed the limit of a single vacuum circuit breaker (VCB).
Xiangyu Han +8 more
semanticscholar +1 more source
IEEE Transactions on Power Systems, 2020
Requirements of economic and reliability criteria are often stressed simultaneously in operating and planning models for distribution systems. However, conventional reliability evaluation algorithms are hard to be integrated to these optimization models ...
Zi-Hao Li +3 more
semanticscholar +1 more source
Requirements of economic and reliability criteria are often stressed simultaneously in operating and planning models for distribution systems. However, conventional reliability evaluation algorithms are hard to be integrated to these optimization models ...
Zi-Hao Li +3 more
semanticscholar +1 more source
Fault Identification for Circuit Breakers Based on Vibration Measurements
IEEE Transactions on Instrumentation and Measurement, 2020Mechanical condition assessment of circuit breakers (CBs) in the power system, if correctly applied, can make an optimal decision on whether, where, and how to perform maintenance.
Qiu-Yu Yang +3 more
semanticscholar +1 more source
International Journal of Electrical Power & Energy Systems, 2020
Vacuum circuit breakers may cause severe reignition overvoltage when switching off inductive loads, which may cause damage to other equipment connected with them, especially in the offshore wind farm power collection system.
Ya-Xun Guo +6 more
semanticscholar +1 more source
Vacuum circuit breakers may cause severe reignition overvoltage when switching off inductive loads, which may cause damage to other equipment connected with them, especially in the offshore wind farm power collection system.
Ya-Xun Guo +6 more
semanticscholar +1 more source
IEEE Transactions on Plasma Science, 2020
Possible sulfur hexafluoride (SF6) gas alternatives have been the focus of research and development in science and industry for many years. After the revision of the European F-Gas regulation 517/2014, the investigation has been even more intensified ...
N. Götte, T. Krampert, P. G. Nikolic
semanticscholar +1 more source
Possible sulfur hexafluoride (SF6) gas alternatives have been the focus of research and development in science and industry for many years. After the revision of the European F-Gas regulation 517/2014, the investigation has been even more intensified ...
N. Götte, T. Krampert, P. G. Nikolic
semanticscholar +1 more source
Prestrike modeling in SF6 circuit breakers
, 2020Prestrike is a common phenomenon in Circuit Breakers (CB) when the moving contact approaching to the fixed contact during the closing operation. This paper focuses on prestrike modeling in SF 6 circuit breakers.
Omid Homaee, A. Gholami
semanticscholar +1 more source
IEEE Transactions on Power Delivery, 2019
High-voltage circuit breakers (HVCBs) play a substantial protection role in power networks. The reliable operation of these critical components leads to an increment of resiliency and safety of power systems.
Fatemeh Nasri Rudsari +2 more
semanticscholar +1 more source
High-voltage circuit breakers (HVCBs) play a substantial protection role in power networks. The reliable operation of these critical components leads to an increment of resiliency and safety of power systems.
Fatemeh Nasri Rudsari +2 more
semanticscholar +1 more source
Analysis and Experimental Validation of Bidirectional Z-Source DC Circuit Breakers
IEEE transactions on industrial electronics (1982. Print), 2020This paper discusses the analysis and experimental validation of bidirectional Z-source breaker and bidirectional Z-source breaker using coupled inductor for low-voltage dc microgrid application.
Swati G. Savaliya, B. Fernandes
semanticscholar +1 more source
Intelligent Failure Diagnosis for Gas Circuit Breakers Based on Dynamic Resistance Measurements
IEEE Transactions on Instrumentation and Measurement, 2019Moving and fixed main and arc contacts used in circuit breakers (CBs) are prone to erosion with time and usage. Static resistance measurement and dynamic resistance measurement (DRM) are well-known noninvasive methods for the condition assessment of the ...
Mohammad Abdollah, A. Razi-Kazemi
semanticscholar +1 more source
High-Voltage Circuit Breakers Technical State Patterns Recognition Based on Machine Learning Methods
IEEE Transactions on Power Delivery, 2019This paper is devoted to improving the assessment of the technical state (health index) of power circuit breakers through the use of machine learning, which allows to formalize expert knowledge, to identify implicit correlations and dependencies, and to ...
A. Khalyasmaa, M. Senyuk, S. Eroshenko
semanticscholar +1 more source