Results 31 to 40 of about 1,862 (211)
The vibration signals generated by transmission and impact of circuit breaker mechanical components have chaotic characteristics, which are difficult to be analyzed with conventional signal processing methods.
Xiaofei XIA, Yufeng LU, Yi SU, Jian YANG
doaj +1 more source
The extraction of current characteristics from the opening and closing coils is a crucial method for monitoring the state of high-voltage circuit breakers.
WANG Shaohe +5 more
doaj +1 more source
Study on working condition of 750 kV AC filter breaker in ± 1100 kV UHVDC system
In this article, the Changji-Guquan ± 1100 kV ultra-high voltage direct current (UHVDC) system has been established by PSCAD software, especially for the arc of the circuit breakers.
Zexin Zhao +4 more
doaj +1 more source
High-voltage circuit breakers are the core equipment in power networks, and to a certain extent, are related to the safe and reliable operation of power systems. However, their core components are prone to mechanical faults.
Yongrong Zhou +3 more
doaj +1 more source
INVESTIGATION OF MECHANICAL STRESSES IN THE DRIVE SHAFT OF MV VACUUM CIRCUIT BREAKER
Introduction. In the last 10-15 years a dominant position in the market of medium voltage circuit breakers, vacuum circuit breakers have taken in which as an actuator mono- or bistable actuators with permanent magnets are used.
E. I. Baida, B. V. Klymenko
doaj +1 more source
High‐voltage direct current fault current interruption: A technology review
This review paper describes fault current interruption principles and various high‐voltage direct currrent (HVDC) circuit breaker technologies. First, fundamentals of HVDC fault current interruption and a generic set of requirements of HVDC circuit ...
Rene P. P. Smeets, Nadew A. Belda
doaj +1 more source
Personalized Network‐Guided Neuromodulation Enhances Human Working Memory
A personalized neuromodulation framework combining individualized functional brain network targeting with real‐time neural decoding is introduced. Using concurrent TMS–fMRI, participant‐specific stimulation targets and optimal frequencies are identified. Only optimal‐frequency stimulation improves working memory across sessions.
Ahsan Khan +13 more
wiley +1 more source
A Multimodal Haptic Feedback Interface with Thin‐Film Compliant Mechanism
Multimodal haptic devices can trigger different mechanoreceptors, enabling richer haptic information. This study presents an electromagnetic multimodal haptic device capable of delivering indentation, stretch, and vibration stimuli. The device is enabled by a novel polymer thin‐film compliant mechanism that provides high translational compliance along ...
Jingjing Wan +15 more
wiley +1 more source
Contact arc time – important parameter of DC high-speed circuit-breakers [PDF]
The parameters of DC high-speed circuit-breakers (HSCB) and test methods are specified in the standards. These standards define requirements of the circuit breakers opening time and the total breaking time.
Rojek Artur, Skrzyniarz Marek
doaj +1 more source
A Robotic Testing Platform for Pipelined Discovery of Resilient Dielectric Elastomer Actuators
This work introduces a robotic testing platform enabling high‐throughput, multi‐parameter lifetime mapping of linear dielectric elastomer actuators (DEAs). By integrating programmable high‐voltage control and automated electromechanical measurements, the system identifies material and operating conditions that double actuator lifetime.
Ang (Leo) Li +10 more
wiley +1 more source

