Results 1 to 10 of about 3,785 (242)
Comparative study between Harmonic FOCUSTM to clamp and tie technique for total thyroidectomy
Background: Thyroid surgery has undergone many changes during the past 2 decades, including the introduction of new surgical techniques such as endoscopic or video-assisted approaches, anesthesia care, intraoperative nerve monitoring and new hemostatic ...
Adil K. Saloom, Mohammed Q. AbdulJabbar
doaj +3 more sources
Background Owing to the increase in both intravenous drug injections and intracardiac and vascular interventional treatments among drug users, the incidence of infective endocarditis (IE) involving the tricuspid valve, which sits between the two right ...
Linfeng Xie +9 more
doaj +2 more sources
Comparative study between Harmonic scalpel, bipolar forceps Diathermy and Classic suture ligation in total thyroidectomy [PDF]
Background: One of the procedures in general surgery that is most regularly carried out is a thyroidectomy.For many thyroid conditions, total thyroidectomy is the preferred course of action, Aim & objectives: The purpose of this study was to contrast
mostafa omara +2 more
doaj +1 more source
IMPACT OF THE HARMONIC SCALPEL HEMOSTASIS IN TOTAL THYROIDECTOMY IN COMPARISON WITH CONVENTIONAL HEMOSTATIC TECHNIQUE [PDF]
Traditional haemostatic technique in thyroidectomy may cause some damages to surrounding tissues and it is time consuming. It is believed that these damages and the time can be reduced using ultrasonic dissector devices like Harmonic Scalpel.
Sadq Ghaleb Kadem +1 more
doaj +1 more source
An Investigation of Leakage Current and Partial Discharge For Various Overhead Insulators
High voltage insulators used in various overhead forms are exposed to leakage current and partial discharge. This work deals with different structure forms of insulator, such as (pin post, clamp top and tie top). These structures are applied in different
Arkan A. Hussein +2 more
doaj +1 more source
LIGASURE VERSUS CLAMP AND TIE TECHNIQUE TO ACHIEVE HEMOSTASIS IN THYROIDECTOMY FOR BENIGN DISEASES
Background:Occurrence of adverse effects and advantages of the Ligasure diathermy system (or Ligasure vessel sealing system) in thyroidectomy have not been tested in prospective randomized studies comparing its use with that of the time-saving clamp-and ...
Tariq I Al-Aubaidi +2 more
doaj +4 more sources
Objectives: The “Tie Grip suture” was designed to fix radial meniscal tears more rigidly than simple conventional sutures. However, one shortcoming was residual gapping at the central margin of the tear.
Daisuke Araki +8 more
doaj +1 more source
Design, qualification & manufacture of ITER gravity supports
As one of the key components to support all the magnet coils, the GS faces engineering challenge to its operational safety throughout the design, qualification and manufacturing process as a result of extreme loading condition.
P.Y. Lee +8 more
doaj +1 more source
Introduction: Longstanding gastrostomy sites are prone to leakage and excoriation secondary to protrusion of gastric mucosa into the tract, dilation of the site over time, and development of refractory granulation tissue.
Rebecca M. Rentea +4 more
doaj +1 more source
ULTRASONIC DISSECTION VERSUS CONVENTIONAL LIGATION COAGULATION IN THYROIDECTOMY [PDF]
ULTRASONIC DISSECTION VERSUS CONVENTIONAL LIGATION COAGULATION IN THYROIDECTOMY Abdulameer Muhsin Aldaraji MB, ChB, FICMS, General Surgeon, Al-Faiha General Hospital, Basrah, IRAQ.
Abdulameer Muhsin Aldaraji
doaj +1 more source