Results 81 to 90 of about 5,109,956 (200)

Equilibrium Paths for von Mises Trusses in Finite Elasticity

open access: yes, 2020
This paper deals with the equilibrium problem of von Mises trusses in nonlinear elasticity. A general loading condition is considered and the rods are regarded as hyperelastic bodies composed of a homogeneous isotropic material.
Pelliciari M., Tarantino A. M.
core   +1 more source

A High Order Theory for Linear Thermoelastic Shells: Comparison with Classical Theories

open access: yesJournal of Engineering, 2013
A high order theory for linear thermoelasticity and heat conductivity of shells has been developed. The proposed theory is based on expansion of the 3-D equations of theory of thermoelasticity and heat conductivity into Fourier series in terms of ...
V. V. Zozulya
doaj   +1 more source

Recyclable Lignin‐Based Thermadapt Shape Memory Polymers With Near‐Infrared Light Response

open access: yesAdvanced Functional Materials, EarlyView.
ABSTRACT Covalent adaptable networks (CANs) have been designed to address the recycling challenges associated with thermosets, while preserving their mechanical properties. However, producing biobased CANs with intelligent response capabilities remains challenging.
Jian Liu   +8 more
wiley   +1 more source

The Gap Between Linear Elasticity and the Variational Limit of Finite Elasticity in Pure Traction Problems [PDF]

open access: yes, 2019
A limit elastic energy for the pure traction problem is derived from re-scaled nonlinear energies of a hyperelastic material body subject to an equilibrated force field.We prove that the strains of minimizing sequences associated to re-scaled nonlinear ...
Francesco Maddalena   +8 more
core   +1 more source

Existence of weak solutions in elasticity

open access: yes, 2013
International audienceSolvability and uniqueness of solutions to the problems of equilibrium, vibration and dynamics in a weak setup for classical and nonclassical models of linear elasticity are established in a unified framework sufficiently flexible ...
Lebedev, Leonid, P.   +1 more
core   +2 more sources

Poisson's Ratio‐Driven Control of Myogenic Differentiation and Maturation in Auxetic Metamaterials under Dynamic Mechanical Stimulation

open access: yesAdvanced Functional Materials, EarlyView.
This study explored how innovative “auxetic” scaffolds, which expand when stretched, influence skeletal muscle development. Researchers cultured muscle cells on different scaffold designs and applied repeated stretching over 10 days. They found that scaffold geometry affected muscle cell differentiation and fiber formation.
Maria Kalogeropoulou   +5 more
wiley   +1 more source

A 3D‐Printed Model of Human Lactation

open access: yesAdvanced Healthcare Materials, EarlyView.
Breastfeeding supports infant and maternal health, yet in vitro models that mimic human lactation remain scarce. Here, light‐based 3D printing creates high‐resolution, alveoli‐inspired microwells that guide breast cells into polarized microtissues. The printed scaffolds embed slow‐release prolactin microcrystals to deliver hormonal cues, enabling human
Amelia Hasenauer, Marcy Zenobi‐Wong
wiley   +1 more source

Closing the Knowledge Gap on Terminal Sterilization of Elastin‐Like Biohybrid Implants

open access: yesAdvanced Healthcare Materials, EarlyView.
Progress in biohybrid medical implants is highly promising, yet ensuring sterility while preserving functionality remains a key challenge for clinical translation. Here, we demonstrate that the choice of sterilization method significantly affects the performance of biohybrid vascular grafts.
Dominic Pascal Andre   +9 more
wiley   +1 more source

That Elusive Elasticity: A Long-Panel Approach to Estimating the Capital-Labor Substitution Elasticity [PDF]

open access: yes
The elasticity of substitution between capital and labor features prominently in several areas of economic research. However, a consensus estimate remains elusive.
Andrew P. Meyer   +2 more
core  

A Wearable Microfluidic Sweat‐Patch Pilot Study for Detecting Breast‐Cancer Proteins CEA and PIP/GCDFP‐15

open access: yesAdvanced Healthcare Materials, EarlyView.
A passive capillary‐driven microfluidic patch standardizes noninvasive sweat collection from the axilla and chest during exercise. Paired sweat and capillary blood samples enable laboratory ELISA analysis of CEA and PIP. CEA is detectable but often below quantification limits, while PIP remains undetectable in sweat.
Fatemeh Esmaeildoost   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy