Results 51 to 60 of about 455,998 (205)

Cygnus A super-resolved via convex optimisation from VLA data [PDF]

open access: yes, 2018
We leverage the Sparsity Averaging Reweighted Analysis (SARA) approach for interferometric imaging, that is based on convex optimisation, for the super-resolution of Cyg A from observations at the frequencies 8.422GHz and 6.678GHz with the Karl G. Jansky
Abdulaziz, Abdullah   +5 more
core   +2 more sources

The Theoretical Astrophysical Observatory: Cloud-Based Mock Galaxy Catalogues

open access: yes, 2016
We introduce the Theoretical Astrophysical Observatory (TAO), an online virtual laboratory that houses mock observations of galaxy survey data. Such mocks have become an integral part of the modern analysis pipeline.
Bernyk, Maksym   +9 more
core   +3 more sources

Environmental Impact Assessment, on the Operation of Conventional and More Electric Large Commercial Aircraft [PDF]

open access: yes, 2013
Global aviation is growing exponentially and there is a great emphasis on trajectory optimization to reduce the overall environmental impact caused by aircraft. Many optimization techniques exist and are being studied for this purpose.
Lawson, Craig P.   +2 more
core   +1 more source

Clean Sky 2 – Project PALACE: Aeration's Experimental Sound Velocity Investigations for High Speed Gerotor Simulations

open access: yesWorld Academy of Science , Engineering and Technology - International Journal ofMechanical and Mechatronics Engineering, 2020
A Gerotor pump is composed of an external and internal gear with conjugate cycloidal profiles. From suction to delivery ports, the fluid is transported inside cavities formed by teeth and driven by the shaft. From a geometric and conceptional side it is worth to note that the internal gear has one tooth less than the external one. Simcenter Amesim v.16
MARY Benoit   +4 more
openaire   +1 more source

The application of compressive sampling to radio astronomy I: Deconvolution

open access: yes, 2011
Compressive sampling is a new paradigm for sampling, based on sparseness of signals or signal representations. It is much less restrictive than Nyquist-Shannon sampling theory and thus explains and systematises the widespread experience that methods such
Beck   +20 more
core   +1 more source

Simulation-Based Assessment of the Control of a Hybrid ECS Including a Vapor Cycle System

open access: yesEngineering Proceedings
Within the Clean Sky 2 regional project, a hybrid environmental control system has been conceived that combines the classical bleed air approach with a vapor cycle cooling in the recirculation air.
Arnav Pathak, Victor Norrefeldt
doaj   +1 more source

Advanced OoA and Automated Technologies for the Manufacturing of a Composite Outer Wing Box

open access: yesMATEC Web of Conferences, 2018
This work resumes the results achieved until today in the European project AirGreen 2 of Clean Sky 2 programme, deriving from the application of two different dry preforming processes for the manufacturing of a composite outer wing box of the next ...
Romano Fulvio   +5 more
doaj   +1 more source

The Next Generation Virgo Cluster Survey - Infrared (NGVS-IR): I. A new Near-UV/Optical/Near-IR Globular Cluster selection tool

open access: yes, 2013
The NGVS-IR project (Next Generation Virgo Survey - Infrared) is a contiguous near-infrared imaging survey of the Virgo cluster of galaxies. It complements the optical wide-field survey of Virgo (NGVS).
Balogh, Michael L.   +37 more
core   +3 more sources

Desarrollos tecnológicos de Aernnova en Clean Sky 2, H2020

open access: yesMATCOMP17 (Composite Materials 2017), 2017
Aernnova's technological developments in Clean Sky 2, H2020 This project has received funding from the Clean Sky 2 Joint Undertaking (JU) under grant agreement CS2-LAP-GAM-2016-2017. The JU receives support from the European Union’s Horizon 2020 research and innovation programme and the Clean Sky 2 JU members other than the Union. The results, opinions,
openaire   +1 more source

NDT for qualification of space hardware made by additive manufacturing

open access: yesResearch and Review Journal of Nondestructive Testing, 2023
X-Ray Computed Tomography (CT) has been established as the preferable NonDestructive Testing (NDT) method to detect inner defects in Metal Additive Manufactured (MAM) parts such as porosity, inclusions, lack of fusion, etc.
Carlos Galleguillos   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy